A prototype coronary electrode catheter for intracoronary electrogram recording

Lawrence T. Weston, Robert W. Hull, John R. Laird, Yem Chin, Dale Wortham

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Successful catheter ablation of accessory pathways is critically dependent on precise pathway localization.1 Rapid and precise pathway localization can also dramatically shorten procedure times. Mapping of left-sided accessory pathways is facilitated by use of the coronary sinus which provides a stable conduit for catheter mapping along the left atrioventricular groove. Mapping of right-sided accessory pathways is technically more difficult and requires an appreciation of the radiographic anatomy of the right atrioventricular groove.2 The right coronary artery courses through the right atrioventricular groove and can provide a means to record right-sided epicardial electrograms. Localization of right-sided accessory pathways using the right coronary artery was first reported in 1990 by Swartz et al.3 In 1991 Lesh et al4 reported their experience with this technique. In both of these investigations, a 2.2Fr wire manufactured for pacing purposes was modified to record unipolar electrograms. The initial experience in a combined total of 10 patients suggested that this technique was safe and effective. The particular technology used in these cases, however, has several disadvantages. First, the recording wire is stiff and subjects patients to the risks of intimal dissection, perforation or coronary artery spasm. Second, repeated mapping requires that the wire traverse the coronary artery each time. Finally, only unipolar electrogram recordings are possible.

Original languageEnglish (US)
Pages (from-to)1492-1493
Number of pages2
JournalThe American journal of cardiology
Volume70
Issue number18
DOIs
StatePublished - Dec 1 1992
Externally publishedYes

Fingerprint

Coronary Vessels
Electrodes
Catheters
Tunica Intima
Catheter Ablation
Coronary Sinus
Spasm
Dissection
Anatomy
Technology

All Science Journal Classification (ASJC) codes

  • Cardiology and Cardiovascular Medicine

Cite this

A prototype coronary electrode catheter for intracoronary electrogram recording. / Weston, Lawrence T.; Hull, Robert W.; Laird, John R.; Chin, Yem; Wortham, Dale.

In: The American journal of cardiology, Vol. 70, No. 18, 01.12.1992, p. 1492-1493.

Research output: Contribution to journalArticle

Weston, Lawrence T. ; Hull, Robert W. ; Laird, John R. ; Chin, Yem ; Wortham, Dale. / A prototype coronary electrode catheter for intracoronary electrogram recording. In: The American journal of cardiology. 1992 ; Vol. 70, No. 18. pp. 1492-1493.
@article{31cc8e15cae34466815b4e6d4a00203f,
title = "A prototype coronary electrode catheter for intracoronary electrogram recording",
abstract = "Successful catheter ablation of accessory pathways is critically dependent on precise pathway localization.1 Rapid and precise pathway localization can also dramatically shorten procedure times. Mapping of left-sided accessory pathways is facilitated by use of the coronary sinus which provides a stable conduit for catheter mapping along the left atrioventricular groove. Mapping of right-sided accessory pathways is technically more difficult and requires an appreciation of the radiographic anatomy of the right atrioventricular groove.2 The right coronary artery courses through the right atrioventricular groove and can provide a means to record right-sided epicardial electrograms. Localization of right-sided accessory pathways using the right coronary artery was first reported in 1990 by Swartz et al.3 In 1991 Lesh et al4 reported their experience with this technique. In both of these investigations, a 2.2Fr wire manufactured for pacing purposes was modified to record unipolar electrograms. The initial experience in a combined total of 10 patients suggested that this technique was safe and effective. The particular technology used in these cases, however, has several disadvantages. First, the recording wire is stiff and subjects patients to the risks of intimal dissection, perforation or coronary artery spasm. Second, repeated mapping requires that the wire traverse the coronary artery each time. Finally, only unipolar electrogram recordings are possible.",
author = "Weston, {Lawrence T.} and Hull, {Robert W.} and Laird, {John R.} and Yem Chin and Dale Wortham",
year = "1992",
month = "12",
day = "1",
doi = "10.1016/0002-9149(92)90307-K",
language = "English (US)",
volume = "70",
pages = "1492--1493",
journal = "American Journal of Cardiology",
issn = "0002-9149",
publisher = "Elsevier Inc.",
number = "18",

}

TY - JOUR

T1 - A prototype coronary electrode catheter for intracoronary electrogram recording

AU - Weston, Lawrence T.

AU - Hull, Robert W.

AU - Laird, John R.

AU - Chin, Yem

AU - Wortham, Dale

PY - 1992/12/1

Y1 - 1992/12/1

N2 - Successful catheter ablation of accessory pathways is critically dependent on precise pathway localization.1 Rapid and precise pathway localization can also dramatically shorten procedure times. Mapping of left-sided accessory pathways is facilitated by use of the coronary sinus which provides a stable conduit for catheter mapping along the left atrioventricular groove. Mapping of right-sided accessory pathways is technically more difficult and requires an appreciation of the radiographic anatomy of the right atrioventricular groove.2 The right coronary artery courses through the right atrioventricular groove and can provide a means to record right-sided epicardial electrograms. Localization of right-sided accessory pathways using the right coronary artery was first reported in 1990 by Swartz et al.3 In 1991 Lesh et al4 reported their experience with this technique. In both of these investigations, a 2.2Fr wire manufactured for pacing purposes was modified to record unipolar electrograms. The initial experience in a combined total of 10 patients suggested that this technique was safe and effective. The particular technology used in these cases, however, has several disadvantages. First, the recording wire is stiff and subjects patients to the risks of intimal dissection, perforation or coronary artery spasm. Second, repeated mapping requires that the wire traverse the coronary artery each time. Finally, only unipolar electrogram recordings are possible.

AB - Successful catheter ablation of accessory pathways is critically dependent on precise pathway localization.1 Rapid and precise pathway localization can also dramatically shorten procedure times. Mapping of left-sided accessory pathways is facilitated by use of the coronary sinus which provides a stable conduit for catheter mapping along the left atrioventricular groove. Mapping of right-sided accessory pathways is technically more difficult and requires an appreciation of the radiographic anatomy of the right atrioventricular groove.2 The right coronary artery courses through the right atrioventricular groove and can provide a means to record right-sided epicardial electrograms. Localization of right-sided accessory pathways using the right coronary artery was first reported in 1990 by Swartz et al.3 In 1991 Lesh et al4 reported their experience with this technique. In both of these investigations, a 2.2Fr wire manufactured for pacing purposes was modified to record unipolar electrograms. The initial experience in a combined total of 10 patients suggested that this technique was safe and effective. The particular technology used in these cases, however, has several disadvantages. First, the recording wire is stiff and subjects patients to the risks of intimal dissection, perforation or coronary artery spasm. Second, repeated mapping requires that the wire traverse the coronary artery each time. Finally, only unipolar electrogram recordings are possible.

UR - http://www.scopus.com/inward/record.url?scp=0026472687&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026472687&partnerID=8YFLogxK

U2 - 10.1016/0002-9149(92)90307-K

DO - 10.1016/0002-9149(92)90307-K

M3 - Article

VL - 70

SP - 1492

EP - 1493

JO - American Journal of Cardiology

JF - American Journal of Cardiology

SN - 0002-9149

IS - 18

ER -