An investigation of new metal framework design for metal ceramic restorations

Kevin H. O'Boyle, Barry K. Norling, David Cagna, Rodney D. Phoenix

Research output: Contribution to journalArticle

19 Citations (Scopus)

Abstract

Statement of problem. Metal ceramic restorations have been implicated in the discoloration of associated gingival tissues. Attempts to remedy this by altering the design of the metal frameworks for such restorations may lead to unacceptable decreases in fracture resistance. Purpose. This study evaluated a new metal framework design for metal-ceramic restorations. Material and methods. Twenty artificial crowns were fabricated with various degrees of facial metal reduction; 0, 1, 2, and 3 mm. The study was conducted in two parts. The first part evaluated changes in light transmission into adjacent root tissue. A light box was fabricated so sample crowns could be illuminated on a mounted natural tooth. The root of the tooth remained outside the light box, and the light transmitted through the crowns into root tissue was measured with a light meter. The second part of the study evaluated changes in fracture strength. The sample crowns were subjected to a vertical load until fracture with use of an Instron machine at a crosshead speed of 1 mm per minute. The load at fracture was recorded. Results. Results indicated a statistically significant increase in light transmission with 1 mm framework reduction or greater, and fracture strengths did not decrease with up to 1 mm of framework reduction. A 1 mm facial axial reduction of the metal framework may be indicated for anterior metal-ceramic restorations. (J Prosthet Dent 1997;78:295-301.).

Original languageEnglish (US)
Pages (from-to)295-301
Number of pages7
JournalJournal of Prosthetic Dentistry
Volume78
Issue number3
DOIs
StatePublished - Sep 1 1997
Externally publishedYes

Fingerprint

Metal Ceramic Alloys
Metals
Crowns
Light
Tooth Root
Tooth

All Science Journal Classification (ASJC) codes

  • Oral Surgery
  • Dentistry(all)

Cite this

An investigation of new metal framework design for metal ceramic restorations. / O'Boyle, Kevin H.; Norling, Barry K.; Cagna, David; Phoenix, Rodney D.

In: Journal of Prosthetic Dentistry, Vol. 78, No. 3, 01.09.1997, p. 295-301.

Research output: Contribution to journalArticle

O'Boyle, Kevin H. ; Norling, Barry K. ; Cagna, David ; Phoenix, Rodney D. / An investigation of new metal framework design for metal ceramic restorations. In: Journal of Prosthetic Dentistry. 1997 ; Vol. 78, No. 3. pp. 295-301.
@article{0d8d0d20fb714664952e3f65d38ea9b2,
title = "An investigation of new metal framework design for metal ceramic restorations",
abstract = "Statement of problem. Metal ceramic restorations have been implicated in the discoloration of associated gingival tissues. Attempts to remedy this by altering the design of the metal frameworks for such restorations may lead to unacceptable decreases in fracture resistance. Purpose. This study evaluated a new metal framework design for metal-ceramic restorations. Material and methods. Twenty artificial crowns were fabricated with various degrees of facial metal reduction; 0, 1, 2, and 3 mm. The study was conducted in two parts. The first part evaluated changes in light transmission into adjacent root tissue. A light box was fabricated so sample crowns could be illuminated on a mounted natural tooth. The root of the tooth remained outside the light box, and the light transmitted through the crowns into root tissue was measured with a light meter. The second part of the study evaluated changes in fracture strength. The sample crowns were subjected to a vertical load until fracture with use of an Instron machine at a crosshead speed of 1 mm per minute. The load at fracture was recorded. Results. Results indicated a statistically significant increase in light transmission with 1 mm framework reduction or greater, and fracture strengths did not decrease with up to 1 mm of framework reduction. A 1 mm facial axial reduction of the metal framework may be indicated for anterior metal-ceramic restorations. (J Prosthet Dent 1997;78:295-301.).",
author = "O'Boyle, {Kevin H.} and Norling, {Barry K.} and David Cagna and Phoenix, {Rodney D.}",
year = "1997",
month = "9",
day = "1",
doi = "10.1016/S0022-3913(97)70029-5",
language = "English (US)",
volume = "78",
pages = "295--301",
journal = "Journal of Prosthetic Dentistry",
issn = "0022-3913",
publisher = "Mosby Inc.",
number = "3",

}

TY - JOUR

T1 - An investigation of new metal framework design for metal ceramic restorations

AU - O'Boyle, Kevin H.

AU - Norling, Barry K.

AU - Cagna, David

AU - Phoenix, Rodney D.

PY - 1997/9/1

Y1 - 1997/9/1

N2 - Statement of problem. Metal ceramic restorations have been implicated in the discoloration of associated gingival tissues. Attempts to remedy this by altering the design of the metal frameworks for such restorations may lead to unacceptable decreases in fracture resistance. Purpose. This study evaluated a new metal framework design for metal-ceramic restorations. Material and methods. Twenty artificial crowns were fabricated with various degrees of facial metal reduction; 0, 1, 2, and 3 mm. The study was conducted in two parts. The first part evaluated changes in light transmission into adjacent root tissue. A light box was fabricated so sample crowns could be illuminated on a mounted natural tooth. The root of the tooth remained outside the light box, and the light transmitted through the crowns into root tissue was measured with a light meter. The second part of the study evaluated changes in fracture strength. The sample crowns were subjected to a vertical load until fracture with use of an Instron machine at a crosshead speed of 1 mm per minute. The load at fracture was recorded. Results. Results indicated a statistically significant increase in light transmission with 1 mm framework reduction or greater, and fracture strengths did not decrease with up to 1 mm of framework reduction. A 1 mm facial axial reduction of the metal framework may be indicated for anterior metal-ceramic restorations. (J Prosthet Dent 1997;78:295-301.).

AB - Statement of problem. Metal ceramic restorations have been implicated in the discoloration of associated gingival tissues. Attempts to remedy this by altering the design of the metal frameworks for such restorations may lead to unacceptable decreases in fracture resistance. Purpose. This study evaluated a new metal framework design for metal-ceramic restorations. Material and methods. Twenty artificial crowns were fabricated with various degrees of facial metal reduction; 0, 1, 2, and 3 mm. The study was conducted in two parts. The first part evaluated changes in light transmission into adjacent root tissue. A light box was fabricated so sample crowns could be illuminated on a mounted natural tooth. The root of the tooth remained outside the light box, and the light transmitted through the crowns into root tissue was measured with a light meter. The second part of the study evaluated changes in fracture strength. The sample crowns were subjected to a vertical load until fracture with use of an Instron machine at a crosshead speed of 1 mm per minute. The load at fracture was recorded. Results. Results indicated a statistically significant increase in light transmission with 1 mm framework reduction or greater, and fracture strengths did not decrease with up to 1 mm of framework reduction. A 1 mm facial axial reduction of the metal framework may be indicated for anterior metal-ceramic restorations. (J Prosthet Dent 1997;78:295-301.).

UR - http://www.scopus.com/inward/record.url?scp=0031226840&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031226840&partnerID=8YFLogxK

U2 - 10.1016/S0022-3913(97)70029-5

DO - 10.1016/S0022-3913(97)70029-5

M3 - Article

VL - 78

SP - 295

EP - 301

JO - Journal of Prosthetic Dentistry

JF - Journal of Prosthetic Dentistry

SN - 0022-3913

IS - 3

ER -