Aneurysm regression after endovascular aneurysm repair

What should we expect?

Hosam F. El Sayed, George H. Meier, Bernardo Mendoza, Larry Richard Sprouse, F. Noel Parent, Jean M. Panneton

Research output: Contribution to journalReview article

4 Citations (Scopus)

Abstract

This study reviewed a large national core laboratory database for the Ancure (Guidant, Menlo Park, California) phase I and II trial of overall aneurysm sac regression after endovascular aneurysm repair. Data were reviewed for aneurysm size and endoleak in follow-up. Endoleak was recorded as well as maximum major and minor axis aortic diameters. Included were patients with baseline assessment within 3 months of implantation and at least 24 months of follow-up, and 444 were available for review. The mean baseline aortic diameter was 56.6 mm; mean follow-up was 48.7 months. Of these patients, 129 (29.5%) had aneurysm regression to less than 40 mm, 42 (9.5%) regressed to less than 35 mm, and 12 (2.7%) had complete aneurysm sac obliteration. Multivariate analysis demonstrated that baseline aneurysm size was the only predictor of aneurysm size regression. Significant sac regression is common after Ancure aneurysm repair and appears to be related primarily to initial aneurysm size.

Original languageEnglish (US)
Pages (from-to)545-550
Number of pages6
JournalVascular and Endovascular Surgery
Volume42
Issue number6
DOIs
StatePublished - Dec 1 2009
Externally publishedYes

Fingerprint

Aneurysm
Endoleak
Multivariate Analysis
Databases

All Science Journal Classification (ASJC) codes

  • Surgery
  • Cardiology and Cardiovascular Medicine

Cite this

Aneurysm regression after endovascular aneurysm repair : What should we expect? / El Sayed, Hosam F.; Meier, George H.; Mendoza, Bernardo; Sprouse, Larry Richard; Parent, F. Noel; Panneton, Jean M.

In: Vascular and Endovascular Surgery, Vol. 42, No. 6, 01.12.2009, p. 545-550.

Research output: Contribution to journalReview article

El Sayed, Hosam F. ; Meier, George H. ; Mendoza, Bernardo ; Sprouse, Larry Richard ; Parent, F. Noel ; Panneton, Jean M. / Aneurysm regression after endovascular aneurysm repair : What should we expect?. In: Vascular and Endovascular Surgery. 2009 ; Vol. 42, No. 6. pp. 545-550.
@article{1ad622d746144bc995e47dcc26cbe3ba,
title = "Aneurysm regression after endovascular aneurysm repair: What should we expect?",
abstract = "This study reviewed a large national core laboratory database for the Ancure (Guidant, Menlo Park, California) phase I and II trial of overall aneurysm sac regression after endovascular aneurysm repair. Data were reviewed for aneurysm size and endoleak in follow-up. Endoleak was recorded as well as maximum major and minor axis aortic diameters. Included were patients with baseline assessment within 3 months of implantation and at least 24 months of follow-up, and 444 were available for review. The mean baseline aortic diameter was 56.6 mm; mean follow-up was 48.7 months. Of these patients, 129 (29.5{\%}) had aneurysm regression to less than 40 mm, 42 (9.5{\%}) regressed to less than 35 mm, and 12 (2.7{\%}) had complete aneurysm sac obliteration. Multivariate analysis demonstrated that baseline aneurysm size was the only predictor of aneurysm size regression. Significant sac regression is common after Ancure aneurysm repair and appears to be related primarily to initial aneurysm size.",
author = "{El Sayed}, {Hosam F.} and Meier, {George H.} and Bernardo Mendoza and Sprouse, {Larry Richard} and Parent, {F. Noel} and Panneton, {Jean M.}",
year = "2009",
month = "12",
day = "1",
doi = "10.1177/1538574408320026",
language = "English (US)",
volume = "42",
pages = "545--550",
journal = "Vascular and Endovascular Surgery",
issn = "1538-5744",
publisher = "SAGE Publications Inc.",
number = "6",

}

TY - JOUR

T1 - Aneurysm regression after endovascular aneurysm repair

T2 - What should we expect?

AU - El Sayed, Hosam F.

AU - Meier, George H.

AU - Mendoza, Bernardo

AU - Sprouse, Larry Richard

AU - Parent, F. Noel

AU - Panneton, Jean M.

PY - 2009/12/1

Y1 - 2009/12/1

N2 - This study reviewed a large national core laboratory database for the Ancure (Guidant, Menlo Park, California) phase I and II trial of overall aneurysm sac regression after endovascular aneurysm repair. Data were reviewed for aneurysm size and endoleak in follow-up. Endoleak was recorded as well as maximum major and minor axis aortic diameters. Included were patients with baseline assessment within 3 months of implantation and at least 24 months of follow-up, and 444 were available for review. The mean baseline aortic diameter was 56.6 mm; mean follow-up was 48.7 months. Of these patients, 129 (29.5%) had aneurysm regression to less than 40 mm, 42 (9.5%) regressed to less than 35 mm, and 12 (2.7%) had complete aneurysm sac obliteration. Multivariate analysis demonstrated that baseline aneurysm size was the only predictor of aneurysm size regression. Significant sac regression is common after Ancure aneurysm repair and appears to be related primarily to initial aneurysm size.

AB - This study reviewed a large national core laboratory database for the Ancure (Guidant, Menlo Park, California) phase I and II trial of overall aneurysm sac regression after endovascular aneurysm repair. Data were reviewed for aneurysm size and endoleak in follow-up. Endoleak was recorded as well as maximum major and minor axis aortic diameters. Included were patients with baseline assessment within 3 months of implantation and at least 24 months of follow-up, and 444 were available for review. The mean baseline aortic diameter was 56.6 mm; mean follow-up was 48.7 months. Of these patients, 129 (29.5%) had aneurysm regression to less than 40 mm, 42 (9.5%) regressed to less than 35 mm, and 12 (2.7%) had complete aneurysm sac obliteration. Multivariate analysis demonstrated that baseline aneurysm size was the only predictor of aneurysm size regression. Significant sac regression is common after Ancure aneurysm repair and appears to be related primarily to initial aneurysm size.

UR - http://www.scopus.com/inward/record.url?scp=58149100225&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=58149100225&partnerID=8YFLogxK

U2 - 10.1177/1538574408320026

DO - 10.1177/1538574408320026

M3 - Review article

VL - 42

SP - 545

EP - 550

JO - Vascular and Endovascular Surgery

JF - Vascular and Endovascular Surgery

SN - 1538-5744

IS - 6

ER -