Biomechanical comparison of internal fixations of the posterior acetabular column

Denis Diangelo, A. Schopfer, T. Hearn, J. Powell, M. Tile

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Three alternative constructs for stabilization of isolated posterior column fractures were assessed by in vitro comparison, as well as the effect of hip flexion, while measuring the stability of the fixation using a specially designed joint simulator. Measurements of stiffness of the intact and reconstructed hemipelvis, and fracture site compliance in three orthogonal directions, were determined. No significant differences were noted in the stiffness values, while greatest stability was achieved by the fixation of a lag screw with a neutralization plate.

Original languageEnglish (US)
Title of host publication1992 Advances in Bioengineering
PublisherPubl by ASME
Pages577-580
Number of pages4
Volume22
ISBN (Print)0791811166
StatePublished - 1992
Externally publishedYes
EventWinter Annual Meeting of the American Society of Mechanical Engineers - Anaheim, CA, USA
Duration: Nov 8 1992Nov 13 1992

Other

OtherWinter Annual Meeting of the American Society of Mechanical Engineers
CityAnaheim, CA, USA
Period11/8/9211/13/92

Fingerprint

Stiffness
Stabilization
Simulators
Compliance

All Science Journal Classification (ASJC) codes

  • Engineering(all)

Cite this

Diangelo, D., Schopfer, A., Hearn, T., Powell, J., & Tile, M. (1992). Biomechanical comparison of internal fixations of the posterior acetabular column. In 1992 Advances in Bioengineering (Vol. 22, pp. 577-580). Publ by ASME.

Biomechanical comparison of internal fixations of the posterior acetabular column. / Diangelo, Denis; Schopfer, A.; Hearn, T.; Powell, J.; Tile, M.

1992 Advances in Bioengineering. Vol. 22 Publ by ASME, 1992. p. 577-580.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Diangelo, D, Schopfer, A, Hearn, T, Powell, J & Tile, M 1992, Biomechanical comparison of internal fixations of the posterior acetabular column. in 1992 Advances in Bioengineering. vol. 22, Publ by ASME, pp. 577-580, Winter Annual Meeting of the American Society of Mechanical Engineers, Anaheim, CA, USA, 11/8/92.
Diangelo D, Schopfer A, Hearn T, Powell J, Tile M. Biomechanical comparison of internal fixations of the posterior acetabular column. In 1992 Advances in Bioengineering. Vol. 22. Publ by ASME. 1992. p. 577-580
Diangelo, Denis ; Schopfer, A. ; Hearn, T. ; Powell, J. ; Tile, M. / Biomechanical comparison of internal fixations of the posterior acetabular column. 1992 Advances in Bioengineering. Vol. 22 Publ by ASME, 1992. pp. 577-580
@inproceedings{9779da086ae44249acfe861a999e8f6d,
title = "Biomechanical comparison of internal fixations of the posterior acetabular column",
abstract = "Three alternative constructs for stabilization of isolated posterior column fractures were assessed by in vitro comparison, as well as the effect of hip flexion, while measuring the stability of the fixation using a specially designed joint simulator. Measurements of stiffness of the intact and reconstructed hemipelvis, and fracture site compliance in three orthogonal directions, were determined. No significant differences were noted in the stiffness values, while greatest stability was achieved by the fixation of a lag screw with a neutralization plate.",
author = "Denis Diangelo and A. Schopfer and T. Hearn and J. Powell and M. Tile",
year = "1992",
language = "English (US)",
isbn = "0791811166",
volume = "22",
pages = "577--580",
booktitle = "1992 Advances in Bioengineering",
publisher = "Publ by ASME",

}

TY - GEN

T1 - Biomechanical comparison of internal fixations of the posterior acetabular column

AU - Diangelo, Denis

AU - Schopfer, A.

AU - Hearn, T.

AU - Powell, J.

AU - Tile, M.

PY - 1992

Y1 - 1992

N2 - Three alternative constructs for stabilization of isolated posterior column fractures were assessed by in vitro comparison, as well as the effect of hip flexion, while measuring the stability of the fixation using a specially designed joint simulator. Measurements of stiffness of the intact and reconstructed hemipelvis, and fracture site compliance in three orthogonal directions, were determined. No significant differences were noted in the stiffness values, while greatest stability was achieved by the fixation of a lag screw with a neutralization plate.

AB - Three alternative constructs for stabilization of isolated posterior column fractures were assessed by in vitro comparison, as well as the effect of hip flexion, while measuring the stability of the fixation using a specially designed joint simulator. Measurements of stiffness of the intact and reconstructed hemipelvis, and fracture site compliance in three orthogonal directions, were determined. No significant differences were noted in the stiffness values, while greatest stability was achieved by the fixation of a lag screw with a neutralization plate.

UR - http://www.scopus.com/inward/record.url?scp=0026985351&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026985351&partnerID=8YFLogxK

M3 - Conference contribution

SN - 0791811166

VL - 22

SP - 577

EP - 580

BT - 1992 Advances in Bioengineering

PB - Publ by ASME