Comparison of a Noninstrumented Immunoassay for Carbamazepine to High Performance Liquid Chromatography and Fluorescence Polarization Immunoassay

Emily B. Cochran, Kenneth L. Massey, Stephanie Phelps, Joyce A. Cramer, Bartlett R. Toftness, Lena S. Denio, Miles E. Drake

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

Summary: The accuracy, precision, and potential clinical utility of a new whole blood, noninstrumented immuno‐chromatographic assay (AccuLevel) for carbamazepine (CBZ) was evaluated in a multicenter trial including 100 pediatric and 205 adult patients. The AccuLevel assay, a fluorescence polarization immunoassay (FPIA), and high‐performance liquid chromatography (HPLC) were used to determine CBZ concentration in samples from 111 female and 194 male patients aged 2–72 years (median 25 years). Mean ± SD plasma CBZ concentrations in all patients were 7.4 ± 3.0 μg/ml with the AccuLevel assay and 7.5 ± 2.9 (μg/ml with FPIA. In 204 patients, the mean concentration determined by the HPLC assay was 7.7 ± 3.0 μ‐g/ml, whereas concentrations determined by the AccuLevel and FPIA assays were 8.0 ± 3.1 and 8.1 ± 3.1μg/ml, respectively. Concentrations determined by the AccuLevel and FPIA assays were significantly higher than those quantified by HPLC (p < 0.05), but not different from each other. In addition, the AccuLevel assay was highly correlated with FPIA (r= 0.97) and HPLC (r= 0.98). Coefficients of variation for the AccuLevel assay at 8 |xg/ml ranged from 6.8 to 7.5% for the three institutions. We conclude that the AccuLevel assay is a simple, reliable method for determining CBZ concentration in a small volume of whole blood and is an acceptable alternative for assessment of CBZ therapy and individualization of CBZ dosage in the physician's office or emergency room. Les auteurs ont étudié la fiabilité, la précision et l'intérêt clinique d'une nouvelle méthode de dosage immuno‐chromatographique non instrumentale de la carbamazepine (Acculevel*) par une etude multicentrique effectuée chez 100 patients pédiatriques et 250 patients adultes. La méthode Acculevel, un immuno‐essai par polarisation de fluorescence (FPIA) et l'HPLC ont été utilisés pour doser le taux sanguin de 111 patients féminins et 194 patients masculins âgés de 2 à 72 ans (mÉdiane: 25 ans). Les taux sanguins moyens de CBZ etaient de 7.4±3.0 μg/ml pour l'Acculevel, contre 7.5±2.9 pour leFPIA. Chez 204 patients, la concentration moyenne dlterminée par HPLC áteit de 7.7±3.0 (μg/ml, les valeurs étant respectivement de 8.0±3.1 et de 8.1±3.1 u.g/ml pour l'Acculevel et le FPIA respectivement. Les concentrations obtenues par Acculevel et par FPIA 6taient significativement plus elevens que celles obtenues par HPLC (p < 0.05), mais ne présentaient pas de différences entre elles. De plus, le dosage Acculevel était très nettement corrélé avec le FPIA (r = 0.97) et l'HPLC (r = 0.98). Le coefficient de variation pour le dosage Acculevel à 8 μg/ml était de 6.8 à 7.5% pur les trois centres participants. Les auteurs concluent que le dosage Acculevel est une méthode simple et fiable de dosage de CBZ dans un petit volume de sang total, et représente une alternative acceptable pour la surveillance d'un traitement par CBZ et pour un dosage de CBZ individuel au cabinet du medecin ou dans un contexte d'urgence. En un ensayo multicéntrico que incluyó 100 enfermos pedi‐átricos y 205 adultos, se ha determinado la precisión y la utilidad clfnica potencial de un nuevo ensayo inmunocromatográfico de sangre completa no instrumental para la carbamazepina (CBZ) (AccuLevel). Para determinar las concentraciones de CBZ en muestras de 111 mujeres y 194 hombre de 2 a 72 años de edad (edad media 25 años) ha sido utilizado el ensayo AccuLevel, un ensayo de fluorescencia por polarizacidn (FPIA) y cromatograffa de lfquidos de alta resolucidn (HPLC), nan sido utilizados. Las concentraciones medias de CBZ en plasma en todos los pa‐cientes fueron de 7.4 ±3.0 u.g/ml con el ensayo AccuLevel y 7.5±2.9 μg/ml con el FPIA. En 204 pacientes la concentration media determinada por el ensayo HPLC fue de 7.7 ±3.0 u.g/ml mientras que las concentraciones determinadas por el AccuLevel y el FPIA fueron 8.0±3.1 y 8.1±3.1 (ig/ml, respectiv‐amente. Las concentraciones determinadas por los ensayos AccuLevel y FPIA fueron significativamente mas elevadas que las cuantificadas mediante el HPLC (p < 0.05), pero no se diferen‐ciaron unas de las otras. Ademas, el ensayo AccuLevel mostro una elevada correlación con el FPIA (r = 0.97) y el HPLC (r = 0.98). Los coeficientes de variacidn para el ensayo de AccuLevel a 8 μg/ml oscilaron de 6.8% a 7.5% en las tres instituciones. Concluimos que el ensayo de AccuLevel es un método simple y fiable para determinar la concentración de CBZ en un volumen muy pequeno de sangre completa y es una alternativa aceptable para dosificar la terapia con CBZ y la individualización de las dosis de CBZ en la oficina del médico o en la sala de urgencia. Die Genauigkeit und Zuverlässigkeit sowie potentielle klinis‐che Nützlichkeit eines neuen nicht‐instrumentalen immunochro‐matographischen Assays zur Carbamazepin‐Bestimmung aus dem Blut (Accu Level) wurde in einer multizentrischen Studie mit 100 pädiatrischen und 205 erwachsenen Patienten bestimmt. Der Accu Level Assay, ein Fluoreszenzpolarisationsimmunoas‐say (FPIA) sowie eine flüssigkeitschromatographische Bestim‐mung (HPLC) wurden zur CBZ Konzentrationsbestimmung bei Proben von 111 weiblichen und 194 mannlichen Patienten von 2 bis 72 Jahren (im Mittel 25 Jahre) benutzt. Die mittleren Plasma CBZ‐Konzentrationen betrugen 7.4 + 3.0 ig/ml mit dem Accu Level‐Assay und 7.5 + 2.9 (μg/ml mit FPIA. Bei 204 Patienten war die mittlere mit HPLC bestimmte Konzentration 7.7 + 3.0 μg/ml gegenuber den mit Accu Level bestimmten Werten von 8.0 + 3.1undFPIA‐Assay bestimmten Werten von 8.1 + 3.1 (μg/ml. Die durch Accu Level und FPIA‐Assay bestimmten Konzentra‐tionen waren signifikant höher als die durch die HPLC bestimmten Konzentrationen (p < 0.05), unterschieden sich jedoch nicht untereinander. Der Accu Level‐Assay zeight eine hohe Ko‐rrelation mit FPIA (r = 0.97) und HPLC (r = 0.98). Die Varia‐tionskoeffizienten fur den Accu Level‐Assay lagen bei 8 mcg/ml zwischen 6.8% bis 7.5% für 3 Institutionen. Wir schlussfolgern, daß der Accu Level‐Assay eine einfache reliable Methode zur CBZ‐Konzentrationsbestimmung in einem kleinen Blutvolumen ist und eine akzeptable Alternative zur Oberwachung der CBZ‐Therapie und individuellen CBZ‐Dosierung sowohl in der Praxis als auch im Notfall darstellt.

Original languageEnglish (US)
Pages (from-to)480-484
Number of pages5
JournalEpilepsia
Volume31
Issue number4
DOIs
StatePublished - Jan 1 1990

Fingerprint

Fluorescence Polarization Immunoassay
Carbamazepine
Immunoassay
Liquid Chromatography
High Pressure Liquid Chromatography
Immunochromatography
Physicians' Offices

All Science Journal Classification (ASJC) codes

  • Neurology
  • Clinical Neurology

Cite this

Comparison of a Noninstrumented Immunoassay for Carbamazepine to High Performance Liquid Chromatography and Fluorescence Polarization Immunoassay. / Cochran, Emily B.; Massey, Kenneth L.; Phelps, Stephanie; Cramer, Joyce A.; Toftness, Bartlett R.; Denio, Lena S.; Drake, Miles E.

In: Epilepsia, Vol. 31, No. 4, 01.01.1990, p. 480-484.

Research output: Contribution to journalArticle

Cochran, Emily B. ; Massey, Kenneth L. ; Phelps, Stephanie ; Cramer, Joyce A. ; Toftness, Bartlett R. ; Denio, Lena S. ; Drake, Miles E. / Comparison of a Noninstrumented Immunoassay for Carbamazepine to High Performance Liquid Chromatography and Fluorescence Polarization Immunoassay. In: Epilepsia. 1990 ; Vol. 31, No. 4. pp. 480-484.
@article{2ec2078fa11d4b27a0e1c091644a0f87,
title = "Comparison of a Noninstrumented Immunoassay for Carbamazepine to High Performance Liquid Chromatography and Fluorescence Polarization Immunoassay",
abstract = "Summary: The accuracy, precision, and potential clinical utility of a new whole blood, noninstrumented immuno‐chromatographic assay (AccuLevel) for carbamazepine (CBZ) was evaluated in a multicenter trial including 100 pediatric and 205 adult patients. The AccuLevel assay, a fluorescence polarization immunoassay (FPIA), and high‐performance liquid chromatography (HPLC) were used to determine CBZ concentration in samples from 111 female and 194 male patients aged 2–72 years (median 25 years). Mean ± SD plasma CBZ concentrations in all patients were 7.4 ± 3.0 μg/ml with the AccuLevel assay and 7.5 ± 2.9 (μg/ml with FPIA. In 204 patients, the mean concentration determined by the HPLC assay was 7.7 ± 3.0 μ‐g/ml, whereas concentrations determined by the AccuLevel and FPIA assays were 8.0 ± 3.1 and 8.1 ± 3.1μg/ml, respectively. Concentrations determined by the AccuLevel and FPIA assays were significantly higher than those quantified by HPLC (p < 0.05), but not different from each other. In addition, the AccuLevel assay was highly correlated with FPIA (r= 0.97) and HPLC (r= 0.98). Coefficients of variation for the AccuLevel assay at 8 |xg/ml ranged from 6.8 to 7.5{\%} for the three institutions. We conclude that the AccuLevel assay is a simple, reliable method for determining CBZ concentration in a small volume of whole blood and is an acceptable alternative for assessment of CBZ therapy and individualization of CBZ dosage in the physician's office or emergency room. Les auteurs ont {\'e}tudi{\'e} la fiabilit{\'e}, la pr{\'e}cision et l'int{\'e}r{\^e}t clinique d'une nouvelle m{\'e}thode de dosage immuno‐chromatographique non instrumentale de la carbamazepine (Acculevel*) par une etude multicentrique effectu{\'e}e chez 100 patients p{\'e}diatriques et 250 patients adultes. La m{\'e}thode Acculevel, un immuno‐essai par polarisation de fluorescence (FPIA) et l'HPLC ont {\'e}t{\'e} utilis{\'e}s pour doser le taux sanguin de 111 patients f{\'e}minins et 194 patients masculins {\^a}g{\'e}s de 2 {\`a} 72 ans (m{\'E}diane: 25 ans). Les taux sanguins moyens de CBZ etaient de 7.4±3.0 μg/ml pour l'Acculevel, contre 7.5±2.9 pour leFPIA. Chez 204 patients, la concentration moyenne dltermin{\'e}e par HPLC {\'a}teit de 7.7±3.0 (μg/ml, les valeurs {\'e}tant respectivement de 8.0±3.1 et de 8.1±3.1 u.g/ml pour l'Acculevel et le FPIA respectivement. Les concentrations obtenues par Acculevel et par FPIA 6taient significativement plus elevens que celles obtenues par HPLC (p < 0.05), mais ne pr{\'e}sentaient pas de diff{\'e}rences entre elles. De plus, le dosage Acculevel {\'e}tait tr{\`e}s nettement corr{\'e}l{\'e} avec le FPIA (r = 0.97) et l'HPLC (r = 0.98). Le coefficient de variation pour le dosage Acculevel {\`a} 8 μg/ml {\'e}tait de 6.8 {\`a} 7.5{\%} pur les trois centres participants. Les auteurs concluent que le dosage Acculevel est une m{\'e}thode simple et fiable de dosage de CBZ dans un petit volume de sang total, et repr{\'e}sente une alternative acceptable pour la surveillance d'un traitement par CBZ et pour un dosage de CBZ individuel au cabinet du medecin ou dans un contexte d'urgence. En un ensayo multic{\'e}ntrico que incluy{\'o} 100 enfermos pedi‐{\'a}tricos y 205 adultos, se ha determinado la precisi{\'o}n y la utilidad clfnica potencial de un nuevo ensayo inmunocromatogr{\'a}fico de sangre completa no instrumental para la carbamazepina (CBZ) (AccuLevel). Para determinar las concentraciones de CBZ en muestras de 111 mujeres y 194 hombre de 2 a 72 a{\~n}os de edad (edad media 25 a{\~n}os) ha sido utilizado el ensayo AccuLevel, un ensayo de fluorescencia por polarizacidn (FPIA) y cromatograffa de lfquidos de alta resolucidn (HPLC), nan sido utilizados. Las concentraciones medias de CBZ en plasma en todos los pa‐cientes fueron de 7.4 ±3.0 u.g/ml con el ensayo AccuLevel y 7.5±2.9 μg/ml con el FPIA. En 204 pacientes la concentration media determinada por el ensayo HPLC fue de 7.7 ±3.0 u.g/ml mientras que las concentraciones determinadas por el AccuLevel y el FPIA fueron 8.0±3.1 y 8.1±3.1 (ig/ml, respectiv‐amente. Las concentraciones determinadas por los ensayos AccuLevel y FPIA fueron significativamente mas elevadas que las cuantificadas mediante el HPLC (p < 0.05), pero no se diferen‐ciaron unas de las otras. Ademas, el ensayo AccuLevel mostro una elevada correlaci{\'o}n con el FPIA (r = 0.97) y el HPLC (r = 0.98). Los coeficientes de variacidn para el ensayo de AccuLevel a 8 μg/ml oscilaron de 6.8{\%} a 7.5{\%} en las tres instituciones. Concluimos que el ensayo de AccuLevel es un m{\'e}todo simple y fiable para determinar la concentraci{\'o}n de CBZ en un volumen muy pequeno de sangre completa y es una alternativa aceptable para dosificar la terapia con CBZ y la individualizaci{\'o}n de las dosis de CBZ en la oficina del m{\'e}dico o en la sala de urgencia. Die Genauigkeit und Zuverl{\"a}ssigkeit sowie potentielle klinis‐che N{\"u}tzlichkeit eines neuen nicht‐instrumentalen immunochro‐matographischen Assays zur Carbamazepin‐Bestimmung aus dem Blut (Accu Level) wurde in einer multizentrischen Studie mit 100 p{\"a}diatrischen und 205 erwachsenen Patienten bestimmt. Der Accu Level Assay, ein Fluoreszenzpolarisationsimmunoas‐say (FPIA) sowie eine fl{\"u}ssigkeitschromatographische Bestim‐mung (HPLC) wurden zur CBZ Konzentrationsbestimmung bei Proben von 111 weiblichen und 194 mannlichen Patienten von 2 bis 72 Jahren (im Mittel 25 Jahre) benutzt. Die mittleren Plasma CBZ‐Konzentrationen betrugen 7.4 + 3.0 ig/ml mit dem Accu Level‐Assay und 7.5 + 2.9 (μg/ml mit FPIA. Bei 204 Patienten war die mittlere mit HPLC bestimmte Konzentration 7.7 + 3.0 μg/ml gegenuber den mit Accu Level bestimmten Werten von 8.0 + 3.1undFPIA‐Assay bestimmten Werten von 8.1 + 3.1 (μg/ml. Die durch Accu Level und FPIA‐Assay bestimmten Konzentra‐tionen waren signifikant h{\"o}her als die durch die HPLC bestimmten Konzentrationen (p < 0.05), unterschieden sich jedoch nicht untereinander. Der Accu Level‐Assay zeight eine hohe Ko‐rrelation mit FPIA (r = 0.97) und HPLC (r = 0.98). Die Varia‐tionskoeffizienten fur den Accu Level‐Assay lagen bei 8 mcg/ml zwischen 6.8{\%} bis 7.5{\%} f{\"u}r 3 Institutionen. Wir schlussfolgern, da{\ss} der Accu Level‐Assay eine einfache reliable Methode zur CBZ‐Konzentrationsbestimmung in einem kleinen Blutvolumen ist und eine akzeptable Alternative zur Oberwachung der CBZ‐Therapie und individuellen CBZ‐Dosierung sowohl in der Praxis als auch im Notfall darstellt.",
author = "Cochran, {Emily B.} and Massey, {Kenneth L.} and Stephanie Phelps and Cramer, {Joyce A.} and Toftness, {Bartlett R.} and Denio, {Lena S.} and Drake, {Miles E.}",
year = "1990",
month = "1",
day = "1",
doi = "10.1111/j.1528-1157.1990.tb05506.x",
language = "English (US)",
volume = "31",
pages = "480--484",
journal = "Epilepsia",
issn = "0013-9580",
publisher = "Wiley-Blackwell",
number = "4",

}

TY - JOUR

T1 - Comparison of a Noninstrumented Immunoassay for Carbamazepine to High Performance Liquid Chromatography and Fluorescence Polarization Immunoassay

AU - Cochran, Emily B.

AU - Massey, Kenneth L.

AU - Phelps, Stephanie

AU - Cramer, Joyce A.

AU - Toftness, Bartlett R.

AU - Denio, Lena S.

AU - Drake, Miles E.

PY - 1990/1/1

Y1 - 1990/1/1

N2 - Summary: The accuracy, precision, and potential clinical utility of a new whole blood, noninstrumented immuno‐chromatographic assay (AccuLevel) for carbamazepine (CBZ) was evaluated in a multicenter trial including 100 pediatric and 205 adult patients. The AccuLevel assay, a fluorescence polarization immunoassay (FPIA), and high‐performance liquid chromatography (HPLC) were used to determine CBZ concentration in samples from 111 female and 194 male patients aged 2–72 years (median 25 years). Mean ± SD plasma CBZ concentrations in all patients were 7.4 ± 3.0 μg/ml with the AccuLevel assay and 7.5 ± 2.9 (μg/ml with FPIA. In 204 patients, the mean concentration determined by the HPLC assay was 7.7 ± 3.0 μ‐g/ml, whereas concentrations determined by the AccuLevel and FPIA assays were 8.0 ± 3.1 and 8.1 ± 3.1μg/ml, respectively. Concentrations determined by the AccuLevel and FPIA assays were significantly higher than those quantified by HPLC (p < 0.05), but not different from each other. In addition, the AccuLevel assay was highly correlated with FPIA (r= 0.97) and HPLC (r= 0.98). Coefficients of variation for the AccuLevel assay at 8 |xg/ml ranged from 6.8 to 7.5% for the three institutions. We conclude that the AccuLevel assay is a simple, reliable method for determining CBZ concentration in a small volume of whole blood and is an acceptable alternative for assessment of CBZ therapy and individualization of CBZ dosage in the physician's office or emergency room. Les auteurs ont étudié la fiabilité, la précision et l'intérêt clinique d'une nouvelle méthode de dosage immuno‐chromatographique non instrumentale de la carbamazepine (Acculevel*) par une etude multicentrique effectuée chez 100 patients pédiatriques et 250 patients adultes. La méthode Acculevel, un immuno‐essai par polarisation de fluorescence (FPIA) et l'HPLC ont été utilisés pour doser le taux sanguin de 111 patients féminins et 194 patients masculins âgés de 2 à 72 ans (mÉdiane: 25 ans). Les taux sanguins moyens de CBZ etaient de 7.4±3.0 μg/ml pour l'Acculevel, contre 7.5±2.9 pour leFPIA. Chez 204 patients, la concentration moyenne dlterminée par HPLC áteit de 7.7±3.0 (μg/ml, les valeurs étant respectivement de 8.0±3.1 et de 8.1±3.1 u.g/ml pour l'Acculevel et le FPIA respectivement. Les concentrations obtenues par Acculevel et par FPIA 6taient significativement plus elevens que celles obtenues par HPLC (p < 0.05), mais ne présentaient pas de différences entre elles. De plus, le dosage Acculevel était très nettement corrélé avec le FPIA (r = 0.97) et l'HPLC (r = 0.98). Le coefficient de variation pour le dosage Acculevel à 8 μg/ml était de 6.8 à 7.5% pur les trois centres participants. Les auteurs concluent que le dosage Acculevel est une méthode simple et fiable de dosage de CBZ dans un petit volume de sang total, et représente une alternative acceptable pour la surveillance d'un traitement par CBZ et pour un dosage de CBZ individuel au cabinet du medecin ou dans un contexte d'urgence. En un ensayo multicéntrico que incluyó 100 enfermos pedi‐átricos y 205 adultos, se ha determinado la precisión y la utilidad clfnica potencial de un nuevo ensayo inmunocromatográfico de sangre completa no instrumental para la carbamazepina (CBZ) (AccuLevel). Para determinar las concentraciones de CBZ en muestras de 111 mujeres y 194 hombre de 2 a 72 años de edad (edad media 25 años) ha sido utilizado el ensayo AccuLevel, un ensayo de fluorescencia por polarizacidn (FPIA) y cromatograffa de lfquidos de alta resolucidn (HPLC), nan sido utilizados. Las concentraciones medias de CBZ en plasma en todos los pa‐cientes fueron de 7.4 ±3.0 u.g/ml con el ensayo AccuLevel y 7.5±2.9 μg/ml con el FPIA. En 204 pacientes la concentration media determinada por el ensayo HPLC fue de 7.7 ±3.0 u.g/ml mientras que las concentraciones determinadas por el AccuLevel y el FPIA fueron 8.0±3.1 y 8.1±3.1 (ig/ml, respectiv‐amente. Las concentraciones determinadas por los ensayos AccuLevel y FPIA fueron significativamente mas elevadas que las cuantificadas mediante el HPLC (p < 0.05), pero no se diferen‐ciaron unas de las otras. Ademas, el ensayo AccuLevel mostro una elevada correlación con el FPIA (r = 0.97) y el HPLC (r = 0.98). Los coeficientes de variacidn para el ensayo de AccuLevel a 8 μg/ml oscilaron de 6.8% a 7.5% en las tres instituciones. Concluimos que el ensayo de AccuLevel es un método simple y fiable para determinar la concentración de CBZ en un volumen muy pequeno de sangre completa y es una alternativa aceptable para dosificar la terapia con CBZ y la individualización de las dosis de CBZ en la oficina del médico o en la sala de urgencia. Die Genauigkeit und Zuverlässigkeit sowie potentielle klinis‐che Nützlichkeit eines neuen nicht‐instrumentalen immunochro‐matographischen Assays zur Carbamazepin‐Bestimmung aus dem Blut (Accu Level) wurde in einer multizentrischen Studie mit 100 pädiatrischen und 205 erwachsenen Patienten bestimmt. Der Accu Level Assay, ein Fluoreszenzpolarisationsimmunoas‐say (FPIA) sowie eine flüssigkeitschromatographische Bestim‐mung (HPLC) wurden zur CBZ Konzentrationsbestimmung bei Proben von 111 weiblichen und 194 mannlichen Patienten von 2 bis 72 Jahren (im Mittel 25 Jahre) benutzt. Die mittleren Plasma CBZ‐Konzentrationen betrugen 7.4 + 3.0 ig/ml mit dem Accu Level‐Assay und 7.5 + 2.9 (μg/ml mit FPIA. Bei 204 Patienten war die mittlere mit HPLC bestimmte Konzentration 7.7 + 3.0 μg/ml gegenuber den mit Accu Level bestimmten Werten von 8.0 + 3.1undFPIA‐Assay bestimmten Werten von 8.1 + 3.1 (μg/ml. Die durch Accu Level und FPIA‐Assay bestimmten Konzentra‐tionen waren signifikant höher als die durch die HPLC bestimmten Konzentrationen (p < 0.05), unterschieden sich jedoch nicht untereinander. Der Accu Level‐Assay zeight eine hohe Ko‐rrelation mit FPIA (r = 0.97) und HPLC (r = 0.98). Die Varia‐tionskoeffizienten fur den Accu Level‐Assay lagen bei 8 mcg/ml zwischen 6.8% bis 7.5% für 3 Institutionen. Wir schlussfolgern, daß der Accu Level‐Assay eine einfache reliable Methode zur CBZ‐Konzentrationsbestimmung in einem kleinen Blutvolumen ist und eine akzeptable Alternative zur Oberwachung der CBZ‐Therapie und individuellen CBZ‐Dosierung sowohl in der Praxis als auch im Notfall darstellt.

AB - Summary: The accuracy, precision, and potential clinical utility of a new whole blood, noninstrumented immuno‐chromatographic assay (AccuLevel) for carbamazepine (CBZ) was evaluated in a multicenter trial including 100 pediatric and 205 adult patients. The AccuLevel assay, a fluorescence polarization immunoassay (FPIA), and high‐performance liquid chromatography (HPLC) were used to determine CBZ concentration in samples from 111 female and 194 male patients aged 2–72 years (median 25 years). Mean ± SD plasma CBZ concentrations in all patients were 7.4 ± 3.0 μg/ml with the AccuLevel assay and 7.5 ± 2.9 (μg/ml with FPIA. In 204 patients, the mean concentration determined by the HPLC assay was 7.7 ± 3.0 μ‐g/ml, whereas concentrations determined by the AccuLevel and FPIA assays were 8.0 ± 3.1 and 8.1 ± 3.1μg/ml, respectively. Concentrations determined by the AccuLevel and FPIA assays were significantly higher than those quantified by HPLC (p < 0.05), but not different from each other. In addition, the AccuLevel assay was highly correlated with FPIA (r= 0.97) and HPLC (r= 0.98). Coefficients of variation for the AccuLevel assay at 8 |xg/ml ranged from 6.8 to 7.5% for the three institutions. We conclude that the AccuLevel assay is a simple, reliable method for determining CBZ concentration in a small volume of whole blood and is an acceptable alternative for assessment of CBZ therapy and individualization of CBZ dosage in the physician's office or emergency room. Les auteurs ont étudié la fiabilité, la précision et l'intérêt clinique d'une nouvelle méthode de dosage immuno‐chromatographique non instrumentale de la carbamazepine (Acculevel*) par une etude multicentrique effectuée chez 100 patients pédiatriques et 250 patients adultes. La méthode Acculevel, un immuno‐essai par polarisation de fluorescence (FPIA) et l'HPLC ont été utilisés pour doser le taux sanguin de 111 patients féminins et 194 patients masculins âgés de 2 à 72 ans (mÉdiane: 25 ans). Les taux sanguins moyens de CBZ etaient de 7.4±3.0 μg/ml pour l'Acculevel, contre 7.5±2.9 pour leFPIA. Chez 204 patients, la concentration moyenne dlterminée par HPLC áteit de 7.7±3.0 (μg/ml, les valeurs étant respectivement de 8.0±3.1 et de 8.1±3.1 u.g/ml pour l'Acculevel et le FPIA respectivement. Les concentrations obtenues par Acculevel et par FPIA 6taient significativement plus elevens que celles obtenues par HPLC (p < 0.05), mais ne présentaient pas de différences entre elles. De plus, le dosage Acculevel était très nettement corrélé avec le FPIA (r = 0.97) et l'HPLC (r = 0.98). Le coefficient de variation pour le dosage Acculevel à 8 μg/ml était de 6.8 à 7.5% pur les trois centres participants. Les auteurs concluent que le dosage Acculevel est une méthode simple et fiable de dosage de CBZ dans un petit volume de sang total, et représente une alternative acceptable pour la surveillance d'un traitement par CBZ et pour un dosage de CBZ individuel au cabinet du medecin ou dans un contexte d'urgence. En un ensayo multicéntrico que incluyó 100 enfermos pedi‐átricos y 205 adultos, se ha determinado la precisión y la utilidad clfnica potencial de un nuevo ensayo inmunocromatográfico de sangre completa no instrumental para la carbamazepina (CBZ) (AccuLevel). Para determinar las concentraciones de CBZ en muestras de 111 mujeres y 194 hombre de 2 a 72 años de edad (edad media 25 años) ha sido utilizado el ensayo AccuLevel, un ensayo de fluorescencia por polarizacidn (FPIA) y cromatograffa de lfquidos de alta resolucidn (HPLC), nan sido utilizados. Las concentraciones medias de CBZ en plasma en todos los pa‐cientes fueron de 7.4 ±3.0 u.g/ml con el ensayo AccuLevel y 7.5±2.9 μg/ml con el FPIA. En 204 pacientes la concentration media determinada por el ensayo HPLC fue de 7.7 ±3.0 u.g/ml mientras que las concentraciones determinadas por el AccuLevel y el FPIA fueron 8.0±3.1 y 8.1±3.1 (ig/ml, respectiv‐amente. Las concentraciones determinadas por los ensayos AccuLevel y FPIA fueron significativamente mas elevadas que las cuantificadas mediante el HPLC (p < 0.05), pero no se diferen‐ciaron unas de las otras. Ademas, el ensayo AccuLevel mostro una elevada correlación con el FPIA (r = 0.97) y el HPLC (r = 0.98). Los coeficientes de variacidn para el ensayo de AccuLevel a 8 μg/ml oscilaron de 6.8% a 7.5% en las tres instituciones. Concluimos que el ensayo de AccuLevel es un método simple y fiable para determinar la concentración de CBZ en un volumen muy pequeno de sangre completa y es una alternativa aceptable para dosificar la terapia con CBZ y la individualización de las dosis de CBZ en la oficina del médico o en la sala de urgencia. Die Genauigkeit und Zuverlässigkeit sowie potentielle klinis‐che Nützlichkeit eines neuen nicht‐instrumentalen immunochro‐matographischen Assays zur Carbamazepin‐Bestimmung aus dem Blut (Accu Level) wurde in einer multizentrischen Studie mit 100 pädiatrischen und 205 erwachsenen Patienten bestimmt. Der Accu Level Assay, ein Fluoreszenzpolarisationsimmunoas‐say (FPIA) sowie eine flüssigkeitschromatographische Bestim‐mung (HPLC) wurden zur CBZ Konzentrationsbestimmung bei Proben von 111 weiblichen und 194 mannlichen Patienten von 2 bis 72 Jahren (im Mittel 25 Jahre) benutzt. Die mittleren Plasma CBZ‐Konzentrationen betrugen 7.4 + 3.0 ig/ml mit dem Accu Level‐Assay und 7.5 + 2.9 (μg/ml mit FPIA. Bei 204 Patienten war die mittlere mit HPLC bestimmte Konzentration 7.7 + 3.0 μg/ml gegenuber den mit Accu Level bestimmten Werten von 8.0 + 3.1undFPIA‐Assay bestimmten Werten von 8.1 + 3.1 (μg/ml. Die durch Accu Level und FPIA‐Assay bestimmten Konzentra‐tionen waren signifikant höher als die durch die HPLC bestimmten Konzentrationen (p < 0.05), unterschieden sich jedoch nicht untereinander. Der Accu Level‐Assay zeight eine hohe Ko‐rrelation mit FPIA (r = 0.97) und HPLC (r = 0.98). Die Varia‐tionskoeffizienten fur den Accu Level‐Assay lagen bei 8 mcg/ml zwischen 6.8% bis 7.5% für 3 Institutionen. Wir schlussfolgern, daß der Accu Level‐Assay eine einfache reliable Methode zur CBZ‐Konzentrationsbestimmung in einem kleinen Blutvolumen ist und eine akzeptable Alternative zur Oberwachung der CBZ‐Therapie und individuellen CBZ‐Dosierung sowohl in der Praxis als auch im Notfall darstellt.

UR - http://www.scopus.com/inward/record.url?scp=0025323083&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025323083&partnerID=8YFLogxK

U2 - 10.1111/j.1528-1157.1990.tb05506.x

DO - 10.1111/j.1528-1157.1990.tb05506.x

M3 - Article

VL - 31

SP - 480

EP - 484

JO - Epilepsia

JF - Epilepsia

SN - 0013-9580

IS - 4

ER -