The concept of using diffuse reflectance spectroscopy to distinguish intraoperatively between pediatric brain tumors and normal brain parenchyma at the edge of resection cavities is evaluated using an in vivo human study. Diffuse reflectance spectra are acquired from normal and tumorous brain areas of 12 pediatric patients during their tumor resection procedures, using a spectroscopic system with a handheld optical probe. A total of 400 spectra are acquired at the rate of 33 Hz from a single investigated site, from which the mean spectrum and the standard deviation are calculated. The mean diffuse reflectance spectra collected are divided into the normal and the tumorous categories in accordance with their corresponding results of histological analysis. Statistical methods are used to identify those spectral features that effectively separated the two tissue categories, and to quantify the spectral variations induced by the motion of the handheld probe during a single spectral acquisition procedure. The results show that diffuse reflectance spectral intensities between 600 and 800 nm are effective in terms of differentiating normal cortex from brain tumors. Furthermore, probe movements induce large variations in spectral intensities (i.e., larger standard deviation) between 400 and 600 nm.

Original languageEnglish (US)
Article number061709
JournalJournal of Biomedical Optics
Volume15
Issue number6
DOIs
StatePublished - Nov 1 2010

Fingerprint

Pediatrics
brain
Tumors
Brain
tumors
Spectroscopy
reflectance
spectroscopy
probes
standard deviation
spectral reflectance
cortexes
acquisition
Statistical methods
Tissue
cavities

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Biomaterials
  • Atomic and Molecular Physics, and Optics
  • Biomedical Engineering

Cite this

Diffuse reflectance spectroscopy for in vivo pediatric brain tumor detection. / Lin, Wei Chiang; Sandberg, David I.; Bhatia, Sanjiv; Johnson, Mahlon; Oh, Sanghoon; Ragheb, John.

In: Journal of Biomedical Optics, Vol. 15, No. 6, 061709, 01.11.2010.

Research output: Contribution to journalArticle

Lin, Wei Chiang ; Sandberg, David I. ; Bhatia, Sanjiv ; Johnson, Mahlon ; Oh, Sanghoon ; Ragheb, John. / Diffuse reflectance spectroscopy for in vivo pediatric brain tumor detection. In: Journal of Biomedical Optics. 2010 ; Vol. 15, No. 6.
@article{464d763749e54a608d144c894e7b40a3,
title = "Diffuse reflectance spectroscopy for in vivo pediatric brain tumor detection",
abstract = "The concept of using diffuse reflectance spectroscopy to distinguish intraoperatively between pediatric brain tumors and normal brain parenchyma at the edge of resection cavities is evaluated using an in vivo human study. Diffuse reflectance spectra are acquired from normal and tumorous brain areas of 12 pediatric patients during their tumor resection procedures, using a spectroscopic system with a handheld optical probe. A total of 400 spectra are acquired at the rate of 33 Hz from a single investigated site, from which the mean spectrum and the standard deviation are calculated. The mean diffuse reflectance spectra collected are divided into the normal and the tumorous categories in accordance with their corresponding results of histological analysis. Statistical methods are used to identify those spectral features that effectively separated the two tissue categories, and to quantify the spectral variations induced by the motion of the handheld probe during a single spectral acquisition procedure. The results show that diffuse reflectance spectral intensities between 600 and 800 nm are effective in terms of differentiating normal cortex from brain tumors. Furthermore, probe movements induce large variations in spectral intensities (i.e., larger standard deviation) between 400 and 600 nm.",
author = "Lin, {Wei Chiang} and Sandberg, {David I.} and Sanjiv Bhatia and Mahlon Johnson and Sanghoon Oh and John Ragheb",
year = "2010",
month = "11",
day = "1",
doi = "10.1117/1.3505012",
language = "English (US)",
volume = "15",
journal = "Journal of Biomedical Optics",
issn = "1083-3668",
publisher = "SPIE",
number = "6",

}

TY - JOUR

T1 - Diffuse reflectance spectroscopy for in vivo pediatric brain tumor detection

AU - Lin, Wei Chiang

AU - Sandberg, David I.

AU - Bhatia, Sanjiv

AU - Johnson, Mahlon

AU - Oh, Sanghoon

AU - Ragheb, John

PY - 2010/11/1

Y1 - 2010/11/1

N2 - The concept of using diffuse reflectance spectroscopy to distinguish intraoperatively between pediatric brain tumors and normal brain parenchyma at the edge of resection cavities is evaluated using an in vivo human study. Diffuse reflectance spectra are acquired from normal and tumorous brain areas of 12 pediatric patients during their tumor resection procedures, using a spectroscopic system with a handheld optical probe. A total of 400 spectra are acquired at the rate of 33 Hz from a single investigated site, from which the mean spectrum and the standard deviation are calculated. The mean diffuse reflectance spectra collected are divided into the normal and the tumorous categories in accordance with their corresponding results of histological analysis. Statistical methods are used to identify those spectral features that effectively separated the two tissue categories, and to quantify the spectral variations induced by the motion of the handheld probe during a single spectral acquisition procedure. The results show that diffuse reflectance spectral intensities between 600 and 800 nm are effective in terms of differentiating normal cortex from brain tumors. Furthermore, probe movements induce large variations in spectral intensities (i.e., larger standard deviation) between 400 and 600 nm.

AB - The concept of using diffuse reflectance spectroscopy to distinguish intraoperatively between pediatric brain tumors and normal brain parenchyma at the edge of resection cavities is evaluated using an in vivo human study. Diffuse reflectance spectra are acquired from normal and tumorous brain areas of 12 pediatric patients during their tumor resection procedures, using a spectroscopic system with a handheld optical probe. A total of 400 spectra are acquired at the rate of 33 Hz from a single investigated site, from which the mean spectrum and the standard deviation are calculated. The mean diffuse reflectance spectra collected are divided into the normal and the tumorous categories in accordance with their corresponding results of histological analysis. Statistical methods are used to identify those spectral features that effectively separated the two tissue categories, and to quantify the spectral variations induced by the motion of the handheld probe during a single spectral acquisition procedure. The results show that diffuse reflectance spectral intensities between 600 and 800 nm are effective in terms of differentiating normal cortex from brain tumors. Furthermore, probe movements induce large variations in spectral intensities (i.e., larger standard deviation) between 400 and 600 nm.

UR - http://www.scopus.com/inward/record.url?scp=79955977579&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79955977579&partnerID=8YFLogxK

U2 - 10.1117/1.3505012

DO - 10.1117/1.3505012

M3 - Article

VL - 15

JO - Journal of Biomedical Optics

JF - Journal of Biomedical Optics

SN - 1083-3668

IS - 6

M1 - 061709

ER -