A double-barreled electrode for simultaneous glutamate iontophoresis and chronic single unit recording from cortical neurons in awake monkeys during voluntary movement is described. Electrode assembly consists of pulling a heated, partitioned capillary tube over a sharpened tungsten rod. Glutamate iontophoresis increased the firing rates of wrist movement related cells an average of 34 Hz during the agonist phase of movement and 27 Hz during the antagonist phase of movement. However, in no case did glutamate iontophoresis alter the detailed structure of the cell's response pattern during wrist movement. This electrode is well suited to chronic recording applications that involve methods such as cross-correlation requiring overlapping activity of neurons and/or muscles. Other applications might involve activation of totally 'silent' neurons to avoid possible sampling bias or to detect effects in post-stimulus time histograms that would otherwise be subliminal.

Original languageEnglish (US)
Pages (from-to)235-242
Number of pages8
JournalJournal of Neuroscience Methods
Volume7
Issue number3
DOIs
StatePublished - Jan 1 1983

Fingerprint

Iontophoresis
Haplorhini
Glutamic Acid
Electrodes
Wrist
Neurons
Tungsten
Selection Bias
Cell Movement
Muscles

All Science Journal Classification (ASJC) codes

  • Neuroscience(all)

Cite this

Double-barreled electrode for simultaneous iontophoresis and single unit recording during movement in awake monkeys. / Kasser, Richard; Cheney, Paul D.

In: Journal of Neuroscience Methods, Vol. 7, No. 3, 01.01.1983, p. 235-242.

Research output: Contribution to journalArticle

@article{9f50fc25167e4c5c977d5e384047d683,
title = "Double-barreled electrode for simultaneous iontophoresis and single unit recording during movement in awake monkeys",
abstract = "A double-barreled electrode for simultaneous glutamate iontophoresis and chronic single unit recording from cortical neurons in awake monkeys during voluntary movement is described. Electrode assembly consists of pulling a heated, partitioned capillary tube over a sharpened tungsten rod. Glutamate iontophoresis increased the firing rates of wrist movement related cells an average of 34 Hz during the agonist phase of movement and 27 Hz during the antagonist phase of movement. However, in no case did glutamate iontophoresis alter the detailed structure of the cell's response pattern during wrist movement. This electrode is well suited to chronic recording applications that involve methods such as cross-correlation requiring overlapping activity of neurons and/or muscles. Other applications might involve activation of totally 'silent' neurons to avoid possible sampling bias or to detect effects in post-stimulus time histograms that would otherwise be subliminal.",
author = "Richard Kasser and Cheney, {Paul D.}",
year = "1983",
month = "1",
day = "1",
doi = "10.1016/0165-0270(83)90005-5",
language = "English (US)",
volume = "7",
pages = "235--242",
journal = "Journal of Neuroscience Methods",
issn = "0165-0270",
publisher = "Elsevier",
number = "3",

}

TY - JOUR

T1 - Double-barreled electrode for simultaneous iontophoresis and single unit recording during movement in awake monkeys

AU - Kasser, Richard

AU - Cheney, Paul D.

PY - 1983/1/1

Y1 - 1983/1/1

N2 - A double-barreled electrode for simultaneous glutamate iontophoresis and chronic single unit recording from cortical neurons in awake monkeys during voluntary movement is described. Electrode assembly consists of pulling a heated, partitioned capillary tube over a sharpened tungsten rod. Glutamate iontophoresis increased the firing rates of wrist movement related cells an average of 34 Hz during the agonist phase of movement and 27 Hz during the antagonist phase of movement. However, in no case did glutamate iontophoresis alter the detailed structure of the cell's response pattern during wrist movement. This electrode is well suited to chronic recording applications that involve methods such as cross-correlation requiring overlapping activity of neurons and/or muscles. Other applications might involve activation of totally 'silent' neurons to avoid possible sampling bias or to detect effects in post-stimulus time histograms that would otherwise be subliminal.

AB - A double-barreled electrode for simultaneous glutamate iontophoresis and chronic single unit recording from cortical neurons in awake monkeys during voluntary movement is described. Electrode assembly consists of pulling a heated, partitioned capillary tube over a sharpened tungsten rod. Glutamate iontophoresis increased the firing rates of wrist movement related cells an average of 34 Hz during the agonist phase of movement and 27 Hz during the antagonist phase of movement. However, in no case did glutamate iontophoresis alter the detailed structure of the cell's response pattern during wrist movement. This electrode is well suited to chronic recording applications that involve methods such as cross-correlation requiring overlapping activity of neurons and/or muscles. Other applications might involve activation of totally 'silent' neurons to avoid possible sampling bias or to detect effects in post-stimulus time histograms that would otherwise be subliminal.

UR - http://www.scopus.com/inward/record.url?scp=0020575386&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0020575386&partnerID=8YFLogxK

U2 - 10.1016/0165-0270(83)90005-5

DO - 10.1016/0165-0270(83)90005-5

M3 - Article

VL - 7

SP - 235

EP - 242

JO - Journal of Neuroscience Methods

JF - Journal of Neuroscience Methods

SN - 0165-0270

IS - 3

ER -