Abstract

When dental implants become infected, the progression of the disease is rapid. Commercially available dental implant surfaces can be easily contaminated, resulting in rapid progression of peri-mucositis and peri-implantitis. The aim of this study was to evaluate, in vitro, the pattern of doxycycline release from by dental implants with titanium nanotube surface (DINS) at different pHs to examine novel drug loading and chemical coating techniques. Nine DINS were loaded with doxycycline and subsequently coated with polylactic-co-glycolic acid (PLGA). High-performance liquid chromatography (HPLC) was used to measure the amounts of released doxycycline in a 30-day period. Cytotoxicity of the DINS was evaluated by an assay using 3-[4,5-dimethylthiazol-2-yl]-2,5 diphenyl tetrazolium bromide (MTT). The results showed that the experimental DINS coated with doxycycline and PLGA showed a mean drug release during the experimental period for the groups: pH 7.4 (8.39 lg/mL), pH 6.4 (8.63 lg/mL). The pH 5.4 (15.18 ll/mL) doxycycline release from DINS was faster at pH 5.4 than those at pHs 6.4 and 7.4 (P ¼ .0031 and .0034, respectively). This new surface treatment of dental implants with titanium nanotubes and subsequent drug loading demonstrated biocompatibility and sustained doxycycline release over a 30-day period. Additional studies are needed in order to adopt a stable drug release at neutral pH environment while warranting a constant drug release in an acidic pH environment.

Original languageEnglish (US)
Pages (from-to)267-273
Number of pages7
JournalJournal of Oral Implantology
Volume45
Issue number4
DOIs
StatePublished - Jan 1 2019

Fingerprint

Nanotubes
Dental Implants
Doxycycline
glycolic acid
Pharmaceutical Preparations
Titanium
Peri-Implantitis
Mucositis
Disease Progression
polylactic acid-polyglycolic acid copolymer
High Pressure Liquid Chromatography
Drug Liberation

All Science Journal Classification (ASJC) codes

  • Oral Surgery

Cite this

Doxycycline release of dental implants with nanotube surface, coated with poly lactic-co-glycolic acid for extended pH-controlled drug delivery. / Alécio, Artur Breno Wanderley; Ferreira, Cimara; Babu, Jegdish; Shokuhfar, Tolou; Jo, Seongbong; Magini, Ricardo; Garcia-Godoy, Franklin.

In: Journal of Oral Implantology, Vol. 45, No. 4, 01.01.2019, p. 267-273.

Research output: Contribution to journalArticle

@article{9714e55843304f948fe419319150af0c,
title = "Doxycycline release of dental implants with nanotube surface, coated with poly lactic-co-glycolic acid for extended pH-controlled drug delivery",
abstract = "When dental implants become infected, the progression of the disease is rapid. Commercially available dental implant surfaces can be easily contaminated, resulting in rapid progression of peri-mucositis and peri-implantitis. The aim of this study was to evaluate, in vitro, the pattern of doxycycline release from by dental implants with titanium nanotube surface (DINS) at different pHs to examine novel drug loading and chemical coating techniques. Nine DINS were loaded with doxycycline and subsequently coated with polylactic-co-glycolic acid (PLGA). High-performance liquid chromatography (HPLC) was used to measure the amounts of released doxycycline in a 30-day period. Cytotoxicity of the DINS was evaluated by an assay using 3-[4,5-dimethylthiazol-2-yl]-2,5 diphenyl tetrazolium bromide (MTT). The results showed that the experimental DINS coated with doxycycline and PLGA showed a mean drug release during the experimental period for the groups: pH 7.4 (8.39 lg/mL), pH 6.4 (8.63 lg/mL). The pH 5.4 (15.18 ll/mL) doxycycline release from DINS was faster at pH 5.4 than those at pHs 6.4 and 7.4 (P ¼ .0031 and .0034, respectively). This new surface treatment of dental implants with titanium nanotubes and subsequent drug loading demonstrated biocompatibility and sustained doxycycline release over a 30-day period. Additional studies are needed in order to adopt a stable drug release at neutral pH environment while warranting a constant drug release in an acidic pH environment.",
author = "Al{\'e}cio, {Artur Breno Wanderley} and Cimara Ferreira and Jegdish Babu and Tolou Shokuhfar and Seongbong Jo and Ricardo Magini and Franklin Garcia-Godoy",
year = "2019",
month = "1",
day = "1",
doi = "10.1563/aaid-joi-D-18-00069",
language = "English (US)",
volume = "45",
pages = "267--273",
journal = "Journal of Oral Implantology",
issn = "0160-6972",
publisher = "Allen Press Inc.",
number = "4",

}

TY - JOUR

T1 - Doxycycline release of dental implants with nanotube surface, coated with poly lactic-co-glycolic acid for extended pH-controlled drug delivery

AU - Alécio, Artur Breno Wanderley

AU - Ferreira, Cimara

AU - Babu, Jegdish

AU - Shokuhfar, Tolou

AU - Jo, Seongbong

AU - Magini, Ricardo

AU - Garcia-Godoy, Franklin

PY - 2019/1/1

Y1 - 2019/1/1

N2 - When dental implants become infected, the progression of the disease is rapid. Commercially available dental implant surfaces can be easily contaminated, resulting in rapid progression of peri-mucositis and peri-implantitis. The aim of this study was to evaluate, in vitro, the pattern of doxycycline release from by dental implants with titanium nanotube surface (DINS) at different pHs to examine novel drug loading and chemical coating techniques. Nine DINS were loaded with doxycycline and subsequently coated with polylactic-co-glycolic acid (PLGA). High-performance liquid chromatography (HPLC) was used to measure the amounts of released doxycycline in a 30-day period. Cytotoxicity of the DINS was evaluated by an assay using 3-[4,5-dimethylthiazol-2-yl]-2,5 diphenyl tetrazolium bromide (MTT). The results showed that the experimental DINS coated with doxycycline and PLGA showed a mean drug release during the experimental period for the groups: pH 7.4 (8.39 lg/mL), pH 6.4 (8.63 lg/mL). The pH 5.4 (15.18 ll/mL) doxycycline release from DINS was faster at pH 5.4 than those at pHs 6.4 and 7.4 (P ¼ .0031 and .0034, respectively). This new surface treatment of dental implants with titanium nanotubes and subsequent drug loading demonstrated biocompatibility and sustained doxycycline release over a 30-day period. Additional studies are needed in order to adopt a stable drug release at neutral pH environment while warranting a constant drug release in an acidic pH environment.

AB - When dental implants become infected, the progression of the disease is rapid. Commercially available dental implant surfaces can be easily contaminated, resulting in rapid progression of peri-mucositis and peri-implantitis. The aim of this study was to evaluate, in vitro, the pattern of doxycycline release from by dental implants with titanium nanotube surface (DINS) at different pHs to examine novel drug loading and chemical coating techniques. Nine DINS were loaded with doxycycline and subsequently coated with polylactic-co-glycolic acid (PLGA). High-performance liquid chromatography (HPLC) was used to measure the amounts of released doxycycline in a 30-day period. Cytotoxicity of the DINS was evaluated by an assay using 3-[4,5-dimethylthiazol-2-yl]-2,5 diphenyl tetrazolium bromide (MTT). The results showed that the experimental DINS coated with doxycycline and PLGA showed a mean drug release during the experimental period for the groups: pH 7.4 (8.39 lg/mL), pH 6.4 (8.63 lg/mL). The pH 5.4 (15.18 ll/mL) doxycycline release from DINS was faster at pH 5.4 than those at pHs 6.4 and 7.4 (P ¼ .0031 and .0034, respectively). This new surface treatment of dental implants with titanium nanotubes and subsequent drug loading demonstrated biocompatibility and sustained doxycycline release over a 30-day period. Additional studies are needed in order to adopt a stable drug release at neutral pH environment while warranting a constant drug release in an acidic pH environment.

UR - http://www.scopus.com/inward/record.url?scp=85072508553&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85072508553&partnerID=8YFLogxK

U2 - 10.1563/aaid-joi-D-18-00069

DO - 10.1563/aaid-joi-D-18-00069

M3 - Article

C2 - 31008689

AN - SCOPUS:85072508553

VL - 45

SP - 267

EP - 273

JO - Journal of Oral Implantology

JF - Journal of Oral Implantology

SN - 0160-6972

IS - 4

ER -