Abstract

Ultra-high molecular weight polyethylene wear debris generated by a prosthetic hip or knee has been linked to osteolysis and the limited lifespan of the implant. However, research results are conflicting with regard to which characteristics of the polyethylene wear debris are most inflammatory. The goal of this study was to determine whether particle size, number, and the presence of endotoxin significantly contribute to increased secretion of pro-inflammatory mediators by macrophages in vitro in response to polyethylene wear debris generated by a hip simulator. The results show that the prevailing inflammatory factor is endotoxin. The macrophages released only minimal levels of TNF-α and IL-6 in response to cleaned polyethylene particles, but these cytokines were released in significantly higher amounts in response to particles spiked with lipopolysaccharide (LPS). The number (up to 500 particles per cell) and size of the particles tested in this study had no significant influence on any of the measured outputs (macrophage viability, TNF-α, IL-6, or PGE2) unless associated with LPS.

Original languageEnglish (US)
Pages (from-to)45-56
Number of pages12
JournalJournal of Long-Term Effects of Medical Implants
Volume24
Issue number1
DOIs
StatePublished - Jan 1 2014

Fingerprint

Ultrahigh molecular weight polyethylenes
Macrophages
Polyethylene
Particle Size
Debris
Endotoxins
Polyethylenes
Particle size
Wear of materials
Lipopolysaccharides
Hip
Interleukin-6
Osteolysis
Prosthetics
Cell Size
Dinoprostone
Knee
Simulators
Cytokines
Research

All Science Journal Classification (ASJC) codes

  • Biomedical Engineering
  • Dentistry(all)

Cite this

Effect of UHMWPE particle size, dose, and endotoxin on in vitro macrophage response. / Alley, Carie; Haggard, Warren; Smith, Richard.

In: Journal of Long-Term Effects of Medical Implants, Vol. 24, No. 1, 01.01.2014, p. 45-56.

Research output: Contribution to journalArticle

@article{5c87243aea4e4a5ca1abcb76928500a6,
title = "Effect of UHMWPE particle size, dose, and endotoxin on in vitro macrophage response",
abstract = "Ultra-high molecular weight polyethylene wear debris generated by a prosthetic hip or knee has been linked to osteolysis and the limited lifespan of the implant. However, research results are conflicting with regard to which characteristics of the polyethylene wear debris are most inflammatory. The goal of this study was to determine whether particle size, number, and the presence of endotoxin significantly contribute to increased secretion of pro-inflammatory mediators by macrophages in vitro in response to polyethylene wear debris generated by a hip simulator. The results show that the prevailing inflammatory factor is endotoxin. The macrophages released only minimal levels of TNF-α and IL-6 in response to cleaned polyethylene particles, but these cytokines were released in significantly higher amounts in response to particles spiked with lipopolysaccharide (LPS). The number (up to 500 particles per cell) and size of the particles tested in this study had no significant influence on any of the measured outputs (macrophage viability, TNF-α, IL-6, or PGE2) unless associated with LPS.",
author = "Carie Alley and Warren Haggard and Richard Smith",
year = "2014",
month = "1",
day = "1",
doi = "10.1615/JLongTermEffMedImplants.2014010273",
language = "English (US)",
volume = "24",
pages = "45--56",
journal = "Journal of Long-Term Effects of Medical Implants",
issn = "1050-6934",
publisher = "Begell House Inc.",
number = "1",

}

TY - JOUR

T1 - Effect of UHMWPE particle size, dose, and endotoxin on in vitro macrophage response

AU - Alley, Carie

AU - Haggard, Warren

AU - Smith, Richard

PY - 2014/1/1

Y1 - 2014/1/1

N2 - Ultra-high molecular weight polyethylene wear debris generated by a prosthetic hip or knee has been linked to osteolysis and the limited lifespan of the implant. However, research results are conflicting with regard to which characteristics of the polyethylene wear debris are most inflammatory. The goal of this study was to determine whether particle size, number, and the presence of endotoxin significantly contribute to increased secretion of pro-inflammatory mediators by macrophages in vitro in response to polyethylene wear debris generated by a hip simulator. The results show that the prevailing inflammatory factor is endotoxin. The macrophages released only minimal levels of TNF-α and IL-6 in response to cleaned polyethylene particles, but these cytokines were released in significantly higher amounts in response to particles spiked with lipopolysaccharide (LPS). The number (up to 500 particles per cell) and size of the particles tested in this study had no significant influence on any of the measured outputs (macrophage viability, TNF-α, IL-6, or PGE2) unless associated with LPS.

AB - Ultra-high molecular weight polyethylene wear debris generated by a prosthetic hip or knee has been linked to osteolysis and the limited lifespan of the implant. However, research results are conflicting with regard to which characteristics of the polyethylene wear debris are most inflammatory. The goal of this study was to determine whether particle size, number, and the presence of endotoxin significantly contribute to increased secretion of pro-inflammatory mediators by macrophages in vitro in response to polyethylene wear debris generated by a hip simulator. The results show that the prevailing inflammatory factor is endotoxin. The macrophages released only minimal levels of TNF-α and IL-6 in response to cleaned polyethylene particles, but these cytokines were released in significantly higher amounts in response to particles spiked with lipopolysaccharide (LPS). The number (up to 500 particles per cell) and size of the particles tested in this study had no significant influence on any of the measured outputs (macrophage viability, TNF-α, IL-6, or PGE2) unless associated with LPS.

UR - http://www.scopus.com/inward/record.url?scp=84896463330&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84896463330&partnerID=8YFLogxK

U2 - 10.1615/JLongTermEffMedImplants.2014010273

DO - 10.1615/JLongTermEffMedImplants.2014010273

M3 - Article

VL - 24

SP - 45

EP - 56

JO - Journal of Long-Term Effects of Medical Implants

JF - Journal of Long-Term Effects of Medical Implants

SN - 1050-6934

IS - 1

ER -