Femoral perforation complicated by pedestal formation in revision hip arthroplasty

Varatharaj Mounasamy, Khaled J. Saleh, William M. Mihalko, Thomas E. Brown

Research output: Contribution to journalArticle

Abstract

We present a case report of a patient in whom intra-operative penetration of the femoral cortex occurred during revision hip surgery. We report this to highlight that femoral perforation can occur at the pedestal while reaming the femoral canal during revision arthroplasty. Distal pedestal, the thick endosteal bone bridge at the tip of the previous stem is often difficult to ream during revision and forcible reaming may perforate the femur. Adequate two view plain radiographs should be taken intra-operatively and the use of guide wires with flexible reamers is advised to avoid perforation.

Original languageEnglish (US)
Pages (from-to)385-387
Number of pages3
JournalEuropean Journal of Orthopaedic Surgery and Traumatology
Volume17
Issue number4
DOIs
StatePublished - Jul 1 2007

Fingerprint

Thigh
Arthroplasty
Hip
Reoperation
Femur
Bone and Bones

All Science Journal Classification (ASJC) codes

  • Surgery
  • Orthopedics and Sports Medicine

Cite this

Femoral perforation complicated by pedestal formation in revision hip arthroplasty. / Mounasamy, Varatharaj; Saleh, Khaled J.; Mihalko, William M.; Brown, Thomas E.

In: European Journal of Orthopaedic Surgery and Traumatology, Vol. 17, No. 4, 01.07.2007, p. 385-387.

Research output: Contribution to journalArticle

@article{4c8742f657a842428554a4802f44a6bd,
title = "Femoral perforation complicated by pedestal formation in revision hip arthroplasty",
abstract = "We present a case report of a patient in whom intra-operative penetration of the femoral cortex occurred during revision hip surgery. We report this to highlight that femoral perforation can occur at the pedestal while reaming the femoral canal during revision arthroplasty. Distal pedestal, the thick endosteal bone bridge at the tip of the previous stem is often difficult to ream during revision and forcible reaming may perforate the femur. Adequate two view plain radiographs should be taken intra-operatively and the use of guide wires with flexible reamers is advised to avoid perforation.",
author = "Varatharaj Mounasamy and Saleh, {Khaled J.} and Mihalko, {William M.} and Brown, {Thomas E.}",
year = "2007",
month = "7",
day = "1",
doi = "10.1007/s00590-007-0193-5",
language = "English (US)",
volume = "17",
pages = "385--387",
journal = "European Journal of Orthopaedic Surgery and Traumatology",
issn = "0948-4817",
publisher = "Springer Verlag",
number = "4",

}

TY - JOUR

T1 - Femoral perforation complicated by pedestal formation in revision hip arthroplasty

AU - Mounasamy, Varatharaj

AU - Saleh, Khaled J.

AU - Mihalko, William M.

AU - Brown, Thomas E.

PY - 2007/7/1

Y1 - 2007/7/1

N2 - We present a case report of a patient in whom intra-operative penetration of the femoral cortex occurred during revision hip surgery. We report this to highlight that femoral perforation can occur at the pedestal while reaming the femoral canal during revision arthroplasty. Distal pedestal, the thick endosteal bone bridge at the tip of the previous stem is often difficult to ream during revision and forcible reaming may perforate the femur. Adequate two view plain radiographs should be taken intra-operatively and the use of guide wires with flexible reamers is advised to avoid perforation.

AB - We present a case report of a patient in whom intra-operative penetration of the femoral cortex occurred during revision hip surgery. We report this to highlight that femoral perforation can occur at the pedestal while reaming the femoral canal during revision arthroplasty. Distal pedestal, the thick endosteal bone bridge at the tip of the previous stem is often difficult to ream during revision and forcible reaming may perforate the femur. Adequate two view plain radiographs should be taken intra-operatively and the use of guide wires with flexible reamers is advised to avoid perforation.

UR - http://www.scopus.com/inward/record.url?scp=36649034893&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=36649034893&partnerID=8YFLogxK

U2 - 10.1007/s00590-007-0193-5

DO - 10.1007/s00590-007-0193-5

M3 - Article

AN - SCOPUS:36649034893

VL - 17

SP - 385

EP - 387

JO - European Journal of Orthopaedic Surgery and Traumatology

JF - European Journal of Orthopaedic Surgery and Traumatology

SN - 0948-4817

IS - 4

ER -