Force sensing system for automated assessment of motor performance during fMRI

Bill Rogers, Wei Zhang, Shalini Narayana, Jack L. Lancaster, Donald A. Robin, Peter T. Fox

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

Finger tapping sequences are a commonly used measure of motor learning in functional imaging studies. Subjects repeat a defined sequence of finger taps as fast as possible for a set period of time. The number of sequences completed per unit time is the measure of performance. Assessment of speed and accuracy is generally accomplished by video recording the session then replaying in slow motion to assess rate and accuracy. This is a time consuming and error prone process. Keyboards and instrumented gloves have also been used for task assessment though they are relatively expensive and not usually compatible in a magnetic resonance imaging (MRI) scanner. To address these problems, we developed a low cost system using MRI compatible force sensitive resistors (FSR) to assess the performance during a finger sequence task. This system additionally provides information on finger coordination including time between sequences, intervals between taps, and tap duration. The method was validated by comparing the FSR system results with results obtained by video analysis during the same session.

Original languageEnglish (US)
Pages (from-to)92-94
Number of pages3
JournalJournal of Neuroscience Methods
Volume190
Issue number1
DOIs
StatePublished - Jun 1 2010

Fingerprint

Fingers
Magnetic Resonance Imaging
Video Recording
Learning
Costs and Cost Analysis

All Science Journal Classification (ASJC) codes

  • Neuroscience(all)

Cite this

Force sensing system for automated assessment of motor performance during fMRI. / Rogers, Bill; Zhang, Wei; Narayana, Shalini; Lancaster, Jack L.; Robin, Donald A.; Fox, Peter T.

In: Journal of Neuroscience Methods, Vol. 190, No. 1, 01.06.2010, p. 92-94.

Research output: Contribution to journalArticle

Rogers, Bill ; Zhang, Wei ; Narayana, Shalini ; Lancaster, Jack L. ; Robin, Donald A. ; Fox, Peter T. / Force sensing system for automated assessment of motor performance during fMRI. In: Journal of Neuroscience Methods. 2010 ; Vol. 190, No. 1. pp. 92-94.
@article{d20e9113fe45459fa27f221fdba6f705,
title = "Force sensing system for automated assessment of motor performance during fMRI",
abstract = "Finger tapping sequences are a commonly used measure of motor learning in functional imaging studies. Subjects repeat a defined sequence of finger taps as fast as possible for a set period of time. The number of sequences completed per unit time is the measure of performance. Assessment of speed and accuracy is generally accomplished by video recording the session then replaying in slow motion to assess rate and accuracy. This is a time consuming and error prone process. Keyboards and instrumented gloves have also been used for task assessment though they are relatively expensive and not usually compatible in a magnetic resonance imaging (MRI) scanner. To address these problems, we developed a low cost system using MRI compatible force sensitive resistors (FSR) to assess the performance during a finger sequence task. This system additionally provides information on finger coordination including time between sequences, intervals between taps, and tap duration. The method was validated by comparing the FSR system results with results obtained by video analysis during the same session.",
author = "Bill Rogers and Wei Zhang and Shalini Narayana and Lancaster, {Jack L.} and Robin, {Donald A.} and Fox, {Peter T.}",
year = "2010",
month = "6",
day = "1",
doi = "10.1016/j.jneumeth.2010.04.011",
language = "English (US)",
volume = "190",
pages = "92--94",
journal = "Journal of Neuroscience Methods",
issn = "0165-0270",
publisher = "Elsevier",
number = "1",

}

TY - JOUR

T1 - Force sensing system for automated assessment of motor performance during fMRI

AU - Rogers, Bill

AU - Zhang, Wei

AU - Narayana, Shalini

AU - Lancaster, Jack L.

AU - Robin, Donald A.

AU - Fox, Peter T.

PY - 2010/6/1

Y1 - 2010/6/1

N2 - Finger tapping sequences are a commonly used measure of motor learning in functional imaging studies. Subjects repeat a defined sequence of finger taps as fast as possible for a set period of time. The number of sequences completed per unit time is the measure of performance. Assessment of speed and accuracy is generally accomplished by video recording the session then replaying in slow motion to assess rate and accuracy. This is a time consuming and error prone process. Keyboards and instrumented gloves have also been used for task assessment though they are relatively expensive and not usually compatible in a magnetic resonance imaging (MRI) scanner. To address these problems, we developed a low cost system using MRI compatible force sensitive resistors (FSR) to assess the performance during a finger sequence task. This system additionally provides information on finger coordination including time between sequences, intervals between taps, and tap duration. The method was validated by comparing the FSR system results with results obtained by video analysis during the same session.

AB - Finger tapping sequences are a commonly used measure of motor learning in functional imaging studies. Subjects repeat a defined sequence of finger taps as fast as possible for a set period of time. The number of sequences completed per unit time is the measure of performance. Assessment of speed and accuracy is generally accomplished by video recording the session then replaying in slow motion to assess rate and accuracy. This is a time consuming and error prone process. Keyboards and instrumented gloves have also been used for task assessment though they are relatively expensive and not usually compatible in a magnetic resonance imaging (MRI) scanner. To address these problems, we developed a low cost system using MRI compatible force sensitive resistors (FSR) to assess the performance during a finger sequence task. This system additionally provides information on finger coordination including time between sequences, intervals between taps, and tap duration. The method was validated by comparing the FSR system results with results obtained by video analysis during the same session.

UR - http://www.scopus.com/inward/record.url?scp=77953701386&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77953701386&partnerID=8YFLogxK

U2 - 10.1016/j.jneumeth.2010.04.011

DO - 10.1016/j.jneumeth.2010.04.011

M3 - Article

VL - 190

SP - 92

EP - 94

JO - Journal of Neuroscience Methods

JF - Journal of Neuroscience Methods

SN - 0165-0270

IS - 1

ER -