Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy

Langston T. Holly, Kevin Foley

Research output: Contribution to journalArticle

73 Citations (Scopus)

Abstract

Study Design. The placement of percutaneous posterior cervical screws using three-dimensional fluoroscopic guidance was performed in intact human cadaver specimens. Objectives. To determine the accuracy and feasibility of placing entirely percutaneous posterior cervical screws using a novel form of spinal image guidance. Summary of Background Data. Conventional image guidance has been shown to increase the accuracy of many open cervical instrumentation procedures. There are presently no published studies reporting this novel method for guiding the percutaneous placement of posterior cervical screws. Methods. An isocentric C-arm was used to obtain CT images of three intact cadaver specimens. A percutaneous dynamic reference array was attached to the C2 spinous process of each specimen. Light-emitting diodes attached to the C-arm were tracked with an electro-optical camera. The image data set was then transferred to the image-guided workstation, which performed an automated registration. Using the workstation, trajectories were planned for bilateral C1-C2 transarticular, C3-C6 lateral mass, and C7 pedicle screw placement. Through 1.5-cm incisions, a drill guide fitted with light-emitting diodes was used for sequential, image-guided drilling, tapping, and placement of cannulated 4.0 mm screws at each level. Postprocedure, thin-cut CT scanning was used to determine the accuracy of screw placement. Results. A total of 41 of 42 percutaneous screws (97.6%) were accurately placed. All of the transarticular atlantoaxial and subaxial lateral mass screws showed no evidence of foramen transversarium, neural foramen, or facet joint violation. One of the C7 pedicle screws had a minor cortical wall violation. Conclusion. This study demonstrates the feasibility of placing percutaneous posterior cervical screws. Three-dimensional fluoroscopy appears to enable highly accurate, percutaneous three-dimensional cervical spine navigation.

Original languageEnglish (US)
Pages (from-to)536-540
Number of pages5
JournalSpine
Volume31
Issue number5
DOIs
StatePublished - Mar 1 2006

Fingerprint

Fluoroscopy
Cadaver
Zygapophyseal Joint
Light
Mandrillus
Feasibility Studies
Spine
Pedicle Screws

All Science Journal Classification (ASJC) codes

  • Orthopedics and Sports Medicine
  • Clinical Neurology

Cite this

Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy. / Holly, Langston T.; Foley, Kevin.

In: Spine, Vol. 31, No. 5, 01.03.2006, p. 536-540.

Research output: Contribution to journalArticle

@article{66348ac882134efb87e05d5d19d4a390,
title = "Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy",
abstract = "Study Design. The placement of percutaneous posterior cervical screws using three-dimensional fluoroscopic guidance was performed in intact human cadaver specimens. Objectives. To determine the accuracy and feasibility of placing entirely percutaneous posterior cervical screws using a novel form of spinal image guidance. Summary of Background Data. Conventional image guidance has been shown to increase the accuracy of many open cervical instrumentation procedures. There are presently no published studies reporting this novel method for guiding the percutaneous placement of posterior cervical screws. Methods. An isocentric C-arm was used to obtain CT images of three intact cadaver specimens. A percutaneous dynamic reference array was attached to the C2 spinous process of each specimen. Light-emitting diodes attached to the C-arm were tracked with an electro-optical camera. The image data set was then transferred to the image-guided workstation, which performed an automated registration. Using the workstation, trajectories were planned for bilateral C1-C2 transarticular, C3-C6 lateral mass, and C7 pedicle screw placement. Through 1.5-cm incisions, a drill guide fitted with light-emitting diodes was used for sequential, image-guided drilling, tapping, and placement of cannulated 4.0 mm screws at each level. Postprocedure, thin-cut CT scanning was used to determine the accuracy of screw placement. Results. A total of 41 of 42 percutaneous screws (97.6{\%}) were accurately placed. All of the transarticular atlantoaxial and subaxial lateral mass screws showed no evidence of foramen transversarium, neural foramen, or facet joint violation. One of the C7 pedicle screws had a minor cortical wall violation. Conclusion. This study demonstrates the feasibility of placing percutaneous posterior cervical screws. Three-dimensional fluoroscopy appears to enable highly accurate, percutaneous three-dimensional cervical spine navigation.",
author = "Holly, {Langston T.} and Kevin Foley",
year = "2006",
month = "3",
day = "1",
doi = "10.1097/01.brs.0000201297.83920.a1",
language = "English (US)",
volume = "31",
pages = "536--540",
journal = "Spine",
issn = "0362-2436",
publisher = "Lippincott Williams and Wilkins",
number = "5",

}

TY - JOUR

T1 - Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy

AU - Holly, Langston T.

AU - Foley, Kevin

PY - 2006/3/1

Y1 - 2006/3/1

N2 - Study Design. The placement of percutaneous posterior cervical screws using three-dimensional fluoroscopic guidance was performed in intact human cadaver specimens. Objectives. To determine the accuracy and feasibility of placing entirely percutaneous posterior cervical screws using a novel form of spinal image guidance. Summary of Background Data. Conventional image guidance has been shown to increase the accuracy of many open cervical instrumentation procedures. There are presently no published studies reporting this novel method for guiding the percutaneous placement of posterior cervical screws. Methods. An isocentric C-arm was used to obtain CT images of three intact cadaver specimens. A percutaneous dynamic reference array was attached to the C2 spinous process of each specimen. Light-emitting diodes attached to the C-arm were tracked with an electro-optical camera. The image data set was then transferred to the image-guided workstation, which performed an automated registration. Using the workstation, trajectories were planned for bilateral C1-C2 transarticular, C3-C6 lateral mass, and C7 pedicle screw placement. Through 1.5-cm incisions, a drill guide fitted with light-emitting diodes was used for sequential, image-guided drilling, tapping, and placement of cannulated 4.0 mm screws at each level. Postprocedure, thin-cut CT scanning was used to determine the accuracy of screw placement. Results. A total of 41 of 42 percutaneous screws (97.6%) were accurately placed. All of the transarticular atlantoaxial and subaxial lateral mass screws showed no evidence of foramen transversarium, neural foramen, or facet joint violation. One of the C7 pedicle screws had a minor cortical wall violation. Conclusion. This study demonstrates the feasibility of placing percutaneous posterior cervical screws. Three-dimensional fluoroscopy appears to enable highly accurate, percutaneous three-dimensional cervical spine navigation.

AB - Study Design. The placement of percutaneous posterior cervical screws using three-dimensional fluoroscopic guidance was performed in intact human cadaver specimens. Objectives. To determine the accuracy and feasibility of placing entirely percutaneous posterior cervical screws using a novel form of spinal image guidance. Summary of Background Data. Conventional image guidance has been shown to increase the accuracy of many open cervical instrumentation procedures. There are presently no published studies reporting this novel method for guiding the percutaneous placement of posterior cervical screws. Methods. An isocentric C-arm was used to obtain CT images of three intact cadaver specimens. A percutaneous dynamic reference array was attached to the C2 spinous process of each specimen. Light-emitting diodes attached to the C-arm were tracked with an electro-optical camera. The image data set was then transferred to the image-guided workstation, which performed an automated registration. Using the workstation, trajectories were planned for bilateral C1-C2 transarticular, C3-C6 lateral mass, and C7 pedicle screw placement. Through 1.5-cm incisions, a drill guide fitted with light-emitting diodes was used for sequential, image-guided drilling, tapping, and placement of cannulated 4.0 mm screws at each level. Postprocedure, thin-cut CT scanning was used to determine the accuracy of screw placement. Results. A total of 41 of 42 percutaneous screws (97.6%) were accurately placed. All of the transarticular atlantoaxial and subaxial lateral mass screws showed no evidence of foramen transversarium, neural foramen, or facet joint violation. One of the C7 pedicle screws had a minor cortical wall violation. Conclusion. This study demonstrates the feasibility of placing percutaneous posterior cervical screws. Three-dimensional fluoroscopy appears to enable highly accurate, percutaneous three-dimensional cervical spine navigation.

UR - http://www.scopus.com/inward/record.url?scp=33645499877&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33645499877&partnerID=8YFLogxK

U2 - 10.1097/01.brs.0000201297.83920.a1

DO - 10.1097/01.brs.0000201297.83920.a1

M3 - Article

C2 - 16508547

AN - SCOPUS:33645499877

VL - 31

SP - 536

EP - 540

JO - Spine

JF - Spine

SN - 0362-2436

IS - 5

ER -