The purpose of this study was to compare the relative efficacy of two methods in assessing the location of the sources of the N100 and P200 components of evoked magnetic fields (EMFs) to transient tone stimuli. EMFs to left ear stimulation, containing both components, were recorded over the right hemisphere of six normal subjects. The magnetic scalp distributions calculated at several adjacent time points, covering the duration of each component's peak, were used to estimate the source parameters of each component. Good estimates of the source of both components were obtained from all magnetic field distributions. The averaged spatial parameters derived from all distributions of each component as well as the parameters derived from the distribution that gave the best source estimate for each component were projected onto magnetic resonance images of subject's head. It was found that the source of each component is located on the superior surface of the temporal lobe and that the source of the P200 component is anterior to the N100 source in all subjects using both procedures.

Original languageEnglish (US)
Pages (from-to)44-48
Number of pages5
JournalExperimental Brain Research
Volume80
Issue number1
DOIs
StatePublished - Apr 1 1990

Fingerprint

Magnetic Fields
Temporal Lobe
Scalp
Ear
Magnetic Resonance Spectroscopy
Head

All Science Journal Classification (ASJC) codes

  • Neuroscience(all)

Cite this

Papanicolaou, A., Rogers, R. L., Baumann, S., Saydjari, C., & Eisenberg, H. M. (1990). Source localization of two evoked magnetic field components using two alternative procedures. Experimental Brain Research, 80(1), 44-48. https://doi.org/10.1007/BF00228845

Source localization of two evoked magnetic field components using two alternative procedures. / Papanicolaou, Andrew; Rogers, R. L.; Baumann, S.; Saydjari, C.; Eisenberg, H. M.

In: Experimental Brain Research, Vol. 80, No. 1, 01.04.1990, p. 44-48.

Research output: Contribution to journalArticle

Papanicolaou, A, Rogers, RL, Baumann, S, Saydjari, C & Eisenberg, HM 1990, 'Source localization of two evoked magnetic field components using two alternative procedures', Experimental Brain Research, vol. 80, no. 1, pp. 44-48. https://doi.org/10.1007/BF00228845
Papanicolaou, Andrew ; Rogers, R. L. ; Baumann, S. ; Saydjari, C. ; Eisenberg, H. M. / Source localization of two evoked magnetic field components using two alternative procedures. In: Experimental Brain Research. 1990 ; Vol. 80, No. 1. pp. 44-48.
@article{585dde02630a4e94a90a557bdf5bf290,
title = "Source localization of two evoked magnetic field components using two alternative procedures",
abstract = "The purpose of this study was to compare the relative efficacy of two methods in assessing the location of the sources of the N100 and P200 components of evoked magnetic fields (EMFs) to transient tone stimuli. EMFs to left ear stimulation, containing both components, were recorded over the right hemisphere of six normal subjects. The magnetic scalp distributions calculated at several adjacent time points, covering the duration of each component's peak, were used to estimate the source parameters of each component. Good estimates of the source of both components were obtained from all magnetic field distributions. The averaged spatial parameters derived from all distributions of each component as well as the parameters derived from the distribution that gave the best source estimate for each component were projected onto magnetic resonance images of subject's head. It was found that the source of each component is located on the superior surface of the temporal lobe and that the source of the P200 component is anterior to the N100 source in all subjects using both procedures.",
author = "Andrew Papanicolaou and Rogers, {R. L.} and S. Baumann and C. Saydjari and Eisenberg, {H. M.}",
year = "1990",
month = "4",
day = "1",
doi = "10.1007/BF00228845",
language = "English (US)",
volume = "80",
pages = "44--48",
journal = "Experimental Brain Research",
issn = "0014-4819",
publisher = "Springer Verlag",
number = "1",

}

TY - JOUR

T1 - Source localization of two evoked magnetic field components using two alternative procedures

AU - Papanicolaou, Andrew

AU - Rogers, R. L.

AU - Baumann, S.

AU - Saydjari, C.

AU - Eisenberg, H. M.

PY - 1990/4/1

Y1 - 1990/4/1

N2 - The purpose of this study was to compare the relative efficacy of two methods in assessing the location of the sources of the N100 and P200 components of evoked magnetic fields (EMFs) to transient tone stimuli. EMFs to left ear stimulation, containing both components, were recorded over the right hemisphere of six normal subjects. The magnetic scalp distributions calculated at several adjacent time points, covering the duration of each component's peak, were used to estimate the source parameters of each component. Good estimates of the source of both components were obtained from all magnetic field distributions. The averaged spatial parameters derived from all distributions of each component as well as the parameters derived from the distribution that gave the best source estimate for each component were projected onto magnetic resonance images of subject's head. It was found that the source of each component is located on the superior surface of the temporal lobe and that the source of the P200 component is anterior to the N100 source in all subjects using both procedures.

AB - The purpose of this study was to compare the relative efficacy of two methods in assessing the location of the sources of the N100 and P200 components of evoked magnetic fields (EMFs) to transient tone stimuli. EMFs to left ear stimulation, containing both components, were recorded over the right hemisphere of six normal subjects. The magnetic scalp distributions calculated at several adjacent time points, covering the duration of each component's peak, were used to estimate the source parameters of each component. Good estimates of the source of both components were obtained from all magnetic field distributions. The averaged spatial parameters derived from all distributions of each component as well as the parameters derived from the distribution that gave the best source estimate for each component were projected onto magnetic resonance images of subject's head. It was found that the source of each component is located on the superior surface of the temporal lobe and that the source of the P200 component is anterior to the N100 source in all subjects using both procedures.

UR - http://www.scopus.com/inward/record.url?scp=0025255124&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025255124&partnerID=8YFLogxK

U2 - 10.1007/BF00228845

DO - 10.1007/BF00228845

M3 - Article

VL - 80

SP - 44

EP - 48

JO - Experimental Brain Research

JF - Experimental Brain Research

SN - 0014-4819

IS - 1

ER -