Abstract

Purpose: Implementation of a conformal small animal image guided microirradiation therapy instrument (microIGRT) consisting of a cone beam microCT subsystem for submillimeter low dose structural imaging image guided radiotherapy and orthovoltage conformal microirradiation with high dose rate and high throughput. Method and Materials: The microCT subsystem is based on an 80kVp micro‐focus x‐ray source with 75×75 μm2 focal spot and a flat panel amorphous silicon detector with 1024×1024 pixels. The irradiator consists of a high power commercially available 320 kVp orthovoltage source with a 0.4×0.4 mm2 focal spot that can be operated at a nominal power of 800W. The beam characteristics are controlled with two variable jaws used to pre‐collimate the radiation beam along each orthogonal direction. An aperture exchange mechanism is used to conform the beam cross section by using computer generated apertures. The microCT radiation dose the orthovoltage source spectral output and dose rate are under evaluation using a mouse digital phantom and a pencil beam algorithm. Results: CT imaging with micrometric resolution is achievable using 128 projections and a maximum radiation dose of 2cGy. Automatic animal positioning and handling is performed within sub‐millimeter precision. The treatment beam can be aimed at different latitude and longitude angles and translated with 500 μm steps. The source was tested to deliver a radiation dose rate of 20 Gy/min when is filtered to a half‐value layer of 4.6 mm Cu. Conclusion: We present our progress and initial tests of a highly conformal image guided small animal microirradiator.

Original languageEnglish (US)
Number of pages1
JournalMedical Physics
Volume37
Issue number6
DOIs
StatePublished - Jan 1 2010
Externally publishedYes

Fingerprint

X-Ray Microtomography
Radiation
Image-Guided Radiotherapy
Silicon
Jaw
X-Rays
Therapeutics

All Science Journal Classification (ASJC) codes

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

TH‐C‐204B‐10 : Implementation of a Small Animal Image Guided Microirradiator: The MicroIGRT. / Izaguirre, Enrique; Chen, H.; su, I.; Silvius, A. A.; Birch, J.; Price, S. G.; Low, D. A.

In: Medical Physics, Vol. 37, No. 6, 01.01.2010.

Research output: Contribution to journalArticle

Izaguirre, Enrique ; Chen, H. ; su, I. ; Silvius, A. A. ; Birch, J. ; Price, S. G. ; Low, D. A. / TH‐C‐204B‐10 : Implementation of a Small Animal Image Guided Microirradiator: The MicroIGRT. In: Medical Physics. 2010 ; Vol. 37, No. 6.
@article{179c7bf7eb8144e18ee092d757913810,
title = "TH‐C‐204B‐10: Implementation of a Small Animal Image Guided Microirradiator: The MicroIGRT",
abstract = "Purpose: Implementation of a conformal small animal image guided microirradiation therapy instrument (microIGRT) consisting of a cone beam microCT subsystem for submillimeter low dose structural imaging image guided radiotherapy and orthovoltage conformal microirradiation with high dose rate and high throughput. Method and Materials: The microCT subsystem is based on an 80kVp micro‐focus x‐ray source with 75×75 μm2 focal spot and a flat panel amorphous silicon detector with 1024×1024 pixels. The irradiator consists of a high power commercially available 320 kVp orthovoltage source with a 0.4×0.4 mm2 focal spot that can be operated at a nominal power of 800W. The beam characteristics are controlled with two variable jaws used to pre‐collimate the radiation beam along each orthogonal direction. An aperture exchange mechanism is used to conform the beam cross section by using computer generated apertures. The microCT radiation dose the orthovoltage source spectral output and dose rate are under evaluation using a mouse digital phantom and a pencil beam algorithm. Results: CT imaging with micrometric resolution is achievable using 128 projections and a maximum radiation dose of 2cGy. Automatic animal positioning and handling is performed within sub‐millimeter precision. The treatment beam can be aimed at different latitude and longitude angles and translated with 500 μm steps. The source was tested to deliver a radiation dose rate of 20 Gy/min when is filtered to a half‐value layer of 4.6 mm Cu. Conclusion: We present our progress and initial tests of a highly conformal image guided small animal microirradiator.",
author = "Enrique Izaguirre and H. Chen and I. su and Silvius, {A. A.} and J. Birch and Price, {S. G.} and Low, {D. A.}",
year = "2010",
month = "1",
day = "1",
doi = "10.1118/1.3469502",
language = "English (US)",
volume = "37",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - TH‐C‐204B‐10

T2 - Implementation of a Small Animal Image Guided Microirradiator: The MicroIGRT

AU - Izaguirre, Enrique

AU - Chen, H.

AU - su, I.

AU - Silvius, A. A.

AU - Birch, J.

AU - Price, S. G.

AU - Low, D. A.

PY - 2010/1/1

Y1 - 2010/1/1

N2 - Purpose: Implementation of a conformal small animal image guided microirradiation therapy instrument (microIGRT) consisting of a cone beam microCT subsystem for submillimeter low dose structural imaging image guided radiotherapy and orthovoltage conformal microirradiation with high dose rate and high throughput. Method and Materials: The microCT subsystem is based on an 80kVp micro‐focus x‐ray source with 75×75 μm2 focal spot and a flat panel amorphous silicon detector with 1024×1024 pixels. The irradiator consists of a high power commercially available 320 kVp orthovoltage source with a 0.4×0.4 mm2 focal spot that can be operated at a nominal power of 800W. The beam characteristics are controlled with two variable jaws used to pre‐collimate the radiation beam along each orthogonal direction. An aperture exchange mechanism is used to conform the beam cross section by using computer generated apertures. The microCT radiation dose the orthovoltage source spectral output and dose rate are under evaluation using a mouse digital phantom and a pencil beam algorithm. Results: CT imaging with micrometric resolution is achievable using 128 projections and a maximum radiation dose of 2cGy. Automatic animal positioning and handling is performed within sub‐millimeter precision. The treatment beam can be aimed at different latitude and longitude angles and translated with 500 μm steps. The source was tested to deliver a radiation dose rate of 20 Gy/min when is filtered to a half‐value layer of 4.6 mm Cu. Conclusion: We present our progress and initial tests of a highly conformal image guided small animal microirradiator.

AB - Purpose: Implementation of a conformal small animal image guided microirradiation therapy instrument (microIGRT) consisting of a cone beam microCT subsystem for submillimeter low dose structural imaging image guided radiotherapy and orthovoltage conformal microirradiation with high dose rate and high throughput. Method and Materials: The microCT subsystem is based on an 80kVp micro‐focus x‐ray source with 75×75 μm2 focal spot and a flat panel amorphous silicon detector with 1024×1024 pixels. The irradiator consists of a high power commercially available 320 kVp orthovoltage source with a 0.4×0.4 mm2 focal spot that can be operated at a nominal power of 800W. The beam characteristics are controlled with two variable jaws used to pre‐collimate the radiation beam along each orthogonal direction. An aperture exchange mechanism is used to conform the beam cross section by using computer generated apertures. The microCT radiation dose the orthovoltage source spectral output and dose rate are under evaluation using a mouse digital phantom and a pencil beam algorithm. Results: CT imaging with micrometric resolution is achievable using 128 projections and a maximum radiation dose of 2cGy. Automatic animal positioning and handling is performed within sub‐millimeter precision. The treatment beam can be aimed at different latitude and longitude angles and translated with 500 μm steps. The source was tested to deliver a radiation dose rate of 20 Gy/min when is filtered to a half‐value layer of 4.6 mm Cu. Conclusion: We present our progress and initial tests of a highly conformal image guided small animal microirradiator.

UR - http://www.scopus.com/inward/record.url?scp=79958831973&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79958831973&partnerID=8YFLogxK

U2 - 10.1118/1.3469502

DO - 10.1118/1.3469502

M3 - Article

VL - 37

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -