The ultrasonix 500RP

A commercial ultrasound research interface

Thaddeus Wilson, James Zagzebski, Tomy Varghese, Quan Chen, Min Rao

Research output: Contribution to journalArticle

33 Citations (Scopus)

Abstract

Unlike researchers in magnetic resonance imaging who have considerable access to high level tools and to data at a very basic level on their scanners, those involved with ultrasound have found little in the way of meaningful and widespread access to even the most basic echo signals in their clinical systems. Interest has emerged, however, in ultrasound research interfaces on commercial scanners to provide access to raw ultrasound data and control of basic research functions. This paper describes initial experience gained on one such ultrasound system. The Ultrasonix 500RP system provides research access to the data at multiple points in the signal processing chain and allows control over most imaging parameters. The Ultrasonix system allows for three methods of research control. One is implemented along with the standard clinical imaging software using "mouseover" screens on the periphery of the application window. These screens are configured by the user to display various signal processing variables, which can be modified in real time. Second, the system can be controlled via a user-written remote control client application interacting through the clinical exam software. Lastly, the user can write a complete application which initializes the basic ultrasound module but need not use the Ultrasonix clinical exam software. All of the modes can be done locally on the scanner itself or via a network, and are based on software developed in C++ with libraries supplied with the scanner. Two examples are presented in this paper from the evaluation of the system in "real world" applications. Measurements of absolute backscatter coefficients and attenuation coefficients versus frequency are shown and elastograms utilizing spatial compounding are described.

Original languageEnglish (US)
Pages (from-to)1772-1781
Number of pages10
JournalIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Volume53
Issue number10
DOIs
StatePublished - Oct 1 2006

Fingerprint

scanners
Ultrasonics
computer programs
signal processing
Signal processing
compounding
remote control
attenuation coefficients
coefficients
Imaging techniques
magnetic resonance
Medical imaging
Magnetic resonance
echoes
Remote control
modules
evaluation

All Science Journal Classification (ASJC) codes

  • Instrumentation
  • Acoustics and Ultrasonics
  • Electrical and Electronic Engineering

Cite this

The ultrasonix 500RP : A commercial ultrasound research interface. / Wilson, Thaddeus; Zagzebski, James; Varghese, Tomy; Chen, Quan; Rao, Min.

In: IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, Vol. 53, No. 10, 01.10.2006, p. 1772-1781.

Research output: Contribution to journalArticle

Wilson, Thaddeus ; Zagzebski, James ; Varghese, Tomy ; Chen, Quan ; Rao, Min. / The ultrasonix 500RP : A commercial ultrasound research interface. In: IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2006 ; Vol. 53, No. 10. pp. 1772-1781.
@article{b7e30a8bf951427295a237e333ff28c3,
title = "The ultrasonix 500RP: A commercial ultrasound research interface",
abstract = "Unlike researchers in magnetic resonance imaging who have considerable access to high level tools and to data at a very basic level on their scanners, those involved with ultrasound have found little in the way of meaningful and widespread access to even the most basic echo signals in their clinical systems. Interest has emerged, however, in ultrasound research interfaces on commercial scanners to provide access to raw ultrasound data and control of basic research functions. This paper describes initial experience gained on one such ultrasound system. The Ultrasonix 500RP system provides research access to the data at multiple points in the signal processing chain and allows control over most imaging parameters. The Ultrasonix system allows for three methods of research control. One is implemented along with the standard clinical imaging software using {"}mouseover{"} screens on the periphery of the application window. These screens are configured by the user to display various signal processing variables, which can be modified in real time. Second, the system can be controlled via a user-written remote control client application interacting through the clinical exam software. Lastly, the user can write a complete application which initializes the basic ultrasound module but need not use the Ultrasonix clinical exam software. All of the modes can be done locally on the scanner itself or via a network, and are based on software developed in C++ with libraries supplied with the scanner. Two examples are presented in this paper from the evaluation of the system in {"}real world{"} applications. Measurements of absolute backscatter coefficients and attenuation coefficients versus frequency are shown and elastograms utilizing spatial compounding are described.",
author = "Thaddeus Wilson and James Zagzebski and Tomy Varghese and Quan Chen and Min Rao",
year = "2006",
month = "10",
day = "1",
doi = "10.1109/TUFFC.2006.110",
language = "English (US)",
volume = "53",
pages = "1772--1781",
journal = "IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control",
issn = "0885-3010",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "10",

}

TY - JOUR

T1 - The ultrasonix 500RP

T2 - A commercial ultrasound research interface

AU - Wilson, Thaddeus

AU - Zagzebski, James

AU - Varghese, Tomy

AU - Chen, Quan

AU - Rao, Min

PY - 2006/10/1

Y1 - 2006/10/1

N2 - Unlike researchers in magnetic resonance imaging who have considerable access to high level tools and to data at a very basic level on their scanners, those involved with ultrasound have found little in the way of meaningful and widespread access to even the most basic echo signals in their clinical systems. Interest has emerged, however, in ultrasound research interfaces on commercial scanners to provide access to raw ultrasound data and control of basic research functions. This paper describes initial experience gained on one such ultrasound system. The Ultrasonix 500RP system provides research access to the data at multiple points in the signal processing chain and allows control over most imaging parameters. The Ultrasonix system allows for three methods of research control. One is implemented along with the standard clinical imaging software using "mouseover" screens on the periphery of the application window. These screens are configured by the user to display various signal processing variables, which can be modified in real time. Second, the system can be controlled via a user-written remote control client application interacting through the clinical exam software. Lastly, the user can write a complete application which initializes the basic ultrasound module but need not use the Ultrasonix clinical exam software. All of the modes can be done locally on the scanner itself or via a network, and are based on software developed in C++ with libraries supplied with the scanner. Two examples are presented in this paper from the evaluation of the system in "real world" applications. Measurements of absolute backscatter coefficients and attenuation coefficients versus frequency are shown and elastograms utilizing spatial compounding are described.

AB - Unlike researchers in magnetic resonance imaging who have considerable access to high level tools and to data at a very basic level on their scanners, those involved with ultrasound have found little in the way of meaningful and widespread access to even the most basic echo signals in their clinical systems. Interest has emerged, however, in ultrasound research interfaces on commercial scanners to provide access to raw ultrasound data and control of basic research functions. This paper describes initial experience gained on one such ultrasound system. The Ultrasonix 500RP system provides research access to the data at multiple points in the signal processing chain and allows control over most imaging parameters. The Ultrasonix system allows for three methods of research control. One is implemented along with the standard clinical imaging software using "mouseover" screens on the periphery of the application window. These screens are configured by the user to display various signal processing variables, which can be modified in real time. Second, the system can be controlled via a user-written remote control client application interacting through the clinical exam software. Lastly, the user can write a complete application which initializes the basic ultrasound module but need not use the Ultrasonix clinical exam software. All of the modes can be done locally on the scanner itself or via a network, and are based on software developed in C++ with libraries supplied with the scanner. Two examples are presented in this paper from the evaluation of the system in "real world" applications. Measurements of absolute backscatter coefficients and attenuation coefficients versus frequency are shown and elastograms utilizing spatial compounding are described.

UR - http://www.scopus.com/inward/record.url?scp=33845635317&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33845635317&partnerID=8YFLogxK

U2 - 10.1109/TUFFC.2006.110

DO - 10.1109/TUFFC.2006.110

M3 - Article

VL - 53

SP - 1772

EP - 1781

JO - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control

JF - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control

SN - 0885-3010

IS - 10

ER -